AO-S-349-FL is a 349 nm Pulsed laser. Used for laser distance measuring, laser radar, laser raman, icp-ms. Key specifications: output / average power 1~100 mW, pulse energy 1~60 uJ, repetition rate 1 Hz-5 kHz. View specifications, datasheet and enquiry options from Precisometer.
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
Laser distance measuring
AO-S-349-FL: 349 nm emission determines compatible optics, coatings and detectors for Laser distance measuring. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
Laser Radar
AO-S-349-FL: 349 nm emission determines compatible optics, coatings and detectors for Laser Radar. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
Laser Raman
AO-S-349-FL: 349 nm emission sets the excitation and detector-band choice for Laser Raman; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (TEM00) also controls focusing and collection geometry.
ICP-MS
AO-S-349-FL: 349 nm emission determines compatible optics, coatings and detectors for ICP-MS. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect AO-S-349-FL to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for AO-S-349-FL
What cooling does the AO-S-349-FL require?+
Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the AO-S-349-FL deliver?+
Transverse mode: TEM00 · M2: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare AO-S-349-FL with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.