Scientific research
AO-S-263-H/1-15uJ: 263 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
Pulse energy, repetition rate, pulse width
AO-S-263-H/1-15uJ is a 263 nm Pulsed laser. Used for scientific research, icp-ms, laser processing, measure. Actively Q-switched UV Laser. Key specifications: operating mode Q-switched, output / average power 1-15 mW. View specifications, datasheet and enquiry options from Precisometer.
Specifications
3 specification rows
| Wavelength | 263 nm |
|---|---|
| Operating mode | Q-switched |
| Output / average power | 1-15 mW |
| Beam / notes | Actively Q-switched UV Laser |
Series-level technical context
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near pulsed lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Nearby series records state M²: <2, M²: <2.0, M²: <1.2, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for AO-S-263-H/1-15uJ; confirm them on the order-specific datasheet.
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
AO-S-263-H/1-15uJ: 263 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
AO-S-263-H/1-15uJ: 263 nm emission determines compatible optics, coatings and detectors for ICP-MS. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
AO-S-263-H/1-15uJ: Laser processing depends on how optical energy is delivered to the target; 263 nm emission governs absorption, while pulse energy, duration and repetition rate governs peak intensity and heat deposition.
AO-S-263-H/1-15uJ: Measure benefits from a stable, focusable source. 263 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare AO-S-263-H/1-15uJ with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | AO-S-263-H/1-15uJ (current) | AO-U-263/1-60uJ | AO-S-261-H |
|---|---|---|---|
| Wavelength | 263 nm | 263 nm | 261 nm |
| Optical power / pulse energy | 1-15 mW | 1-200 mW | 1~15 mW |
| Operating mode / pulse width | Q-switched | Q-switched | 1 Hz-1 kHz |
| Beam quality | Confirm for this model | Confirm for this model | Near TEM00 |
Compare the AO-S-263-H/1-15uJ with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide