Back to Home

Pulse energy, repetition rate, pulse width

AO-S-261-H261 nm deep-UV Q-switched pulsed laser

261 nm

AO-S-261-H is a 261 nm Pulsed laser. Used for material processing, measure, scientific research. Key specifications: output / average power 1~15 mW, pulse energy 1~15 uJ, repetition rate 1 Hz-1 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

AO-S-261-H

18 specification rows

Wavelength261 nm
Output / average power1~15 mW
Pulse energy1~15 uJ
Repetition rate1 Hz-1 kHz
Pulse width~9 ns
Operating modeActively Q-switched
Power stability (rms, 4 hours, ±3°C)<5%, <3%, <2%
Transverse modeNear TEM00
M2<2
Beam diameter at the aperture 1/e2 (mm)<1.5
Warm-up time (minutes)<10
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-AOM-DL
Expected lifetime (hours)>10000
Pulse duration (ns)~9
Rep. rate1Hz-1kHz
<2
Beam divergence, full angle (mrad)<1.5
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Material processing

AO-S-261-H: Material processing depends on how optical energy is delivered to the target; 261 nm emission governs absorption, while the listed temporal parameter (1~15 uJ) governs peak intensity and heat deposition.

Measure

AO-S-261-H: Measure benefits from a stable, focusable source. 261 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (Near TEM00) informs waist size and propagation.

Scientific research

AO-S-261-H: 261 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect AO-S-261-H to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · M2: <2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for AO-S-261-H

What cooling does the AO-S-261-H require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the AO-S-261-H deliver?

Transverse mode: Near TEM00 · M2: <2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare AO-S-261-H with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterAO-S-261-H (current)AO-S-261-H/1-15uJAO-S-263-H/1-15uJ
Wavelength261 nm261 nm263 nm
Optical power / pulse energy1~15 mW1-15 mW1-15 mW
Operating mode / pulse width1 Hz-1 kHzQ-switchedQ-switched
Beam qualityNear TEM00Confirm for this modelConfirm for this model