Back to Home

Pulse energy, repetition rate, pulse width

420 ~ 1200420~1200 nm infrared tunable pulsed laser

420~1200 nm

420 ~ 1200 is a 420~1200 nm Pulsed laser. Used for scientific research, medical treatment, remote sensing, spectroscopy. Rep. rate (Hz): 10; Cooled method: Water cooled. Key specifications: pulse energy 1-20 mJ, repetition rate 10 Hz, pulse width <8 ns. View specifications, datasheet and enquiry options from Precisometer.

Specifications

420 ~ 1200

5 specification rows

Wavelength420~1200 nm
Pulse energy1-20 mJ
Repetition rate10 Hz
Beam / notesRep. rate (Hz): 10; Cooled method: Water cooled
Pulse width<8 ns
CoolingWater cooled

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Scientific research

420 ~ 1200: 420~1200 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Medical treatment

420 ~ 1200: 420~1200 nm emission determines compatible optics, coatings and detectors for Medical treatment. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Remote sensing

420 ~ 1200: 420~1200 nm emission determines compatible optics, coatings and detectors for Remote sensing. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Spectroscopy

420 ~ 1200: 420~1200 nm emission sets the excitation and detector-band choice for Spectroscopy; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.

System integration

Integration and compatibility

Use these checks to connect 420 ~ 1200 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooling: Water cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Technical FAQ

Integration questions for 420 ~ 1200

What cooling does the 420 ~ 1200 require?

Cooling: Water cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare 420 ~ 1200 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameter420 ~ 1200 (current)710 ~ 8102 13
Wavelength420~1200 nm710~810 nm213 nm
Optical power / pulse energy1-20 mJ1-20 mJ1-100 uJ
Operating mode / pulse width10 Hz1-20 Hz100 Hz-10 kHz
Beam qualityConfirm for this modelConfirm for this modelConfirm for this model