Optical instrumentation
VUV-193: 193 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
Pulse energy, repetition rate, pulse width
VUV-193 is a 193 nm Pulsed laser. Water cooled. Key specifications: output / average power 1~10 mW, pulse energy 0.1~2 uJ, operating mode Actively Q-switched. View specifications, datasheet and enquiry options from Precisometer.
Specifications
17 specification rows
| Output / average power | 1~10 mW |
|---|---|
| Pulse energy | 0.1~2 uJ |
| Beam / notes | Water cooled |
| Operating mode | Actively Q-switched |
| Rep.rate (kHz) | 5 |
| Pulse duration (ns) | ~10 |
| Ave power stability (rms, 4 hours±3℃) | <5%, <3% |
| Polarization ratio | >50:1 Horizontal |
| Operating temperature (℃) | 10-35 |
| Power supply (100-240VAC) | RAD1PS |
| Wavelength (nm) | 193±1 |
| Single pulse energy (µJ) | 0.1-2 |
| Peak power(W) | 1-200 |
| Beam diameter at the aperture (1/e2, mm) | ~2×3 |
| Warm-up time (minutes) | <10 |
| Beam height from base plate (mm) | 134 |
| Cooled method | Water cooled |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
VUV-193: 193 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
VUV-193: Laboratory measurement benefits from a stable, focusable source. 193 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
System integration
Use these checks to connect VUV-193 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (℃): 10-35 · Cooled method: Water cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Polarization ratio: >50:1 Horizontal · Beam diameter at the aperture (1/e2, mm): ~2×3. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare VUV-193 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | VUV-193 (current) | 2 13 | DPS-213-Pico |
|---|---|---|---|
| Wavelength | 193 nm | 213 nm | 213 nm |
| Optical power / pulse energy | 1~10 mW | 1-100 uJ | 1~30 mW |
| Operating mode / pulse width | Actively Q-switched | 100 Hz-10 kHz | Pulsed |
| Beam quality | Confirm for this model | Confirm for this model | <3 |
Compare the VUV-193 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide