Scientific research
DPS-213-Pico: 213 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.
Pulse energy, repetition rate, pulse width
DPS-213-Pico is a 213 nm Pulsed laser. Used for scientific research, fluorescence lifetime measurement. Pulse duration <50ps @5MHz. Key specifications: operating mode Pulsed, output / average power 1~30 mW, power stability (rms) <5%, <3%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
16 specification rows
| Operating mode | Pulsed |
|---|---|
| Output / average power | 1~30 mW |
| Beam / notes | Pulse duration <50 ps @5 MHz |
| Power stability (rms) | <5%, <3% |
| Pulse width (ps) | <50 |
| Jitter (ns, sdev) | <1ns |
| Beam divergence, full angle (mrad) | <3 |
| Beam diameter (mm) | ~2 |
| Rep. rate | 5MHz |
| Cooled method | Air cooled |
| Warm-up time (minutes) | <15 |
| Operating temperature (℃) | 15-30 |
| Power supply (110/220VAC) | PSU-DPS-Pico |
| Wavelength (nm) | 213±1 |
| Average power (mW) | 1-30 |
| Beam height from base plate (mm) | 157 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
DPS-213-Pico: 213 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.
DPS-213-Pico: 213 nm emission can be matched to the absorption or excitation band used in Fluorescence lifetime measurement. The stated stability or noise figure (<5%, <3%) helps keep measured intensity changes attributable to the sample rather than source drift.
System integration
Use these checks to connect DPS-213-Pico to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Air cooled · Operating temperature (℃): 15-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam divergence, full angle (mrad): <3 · Beam diameter (mm): ~2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare DPS-213-Pico with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | DPS-213-Pico (current) | 2 13 | EO-213-Subnano-Hi |
|---|---|---|---|
| Wavelength | 213 nm | 213 nm | 213 nm |
| Optical power / pulse energy | 1~30 mW | 1-100 uJ | 1-100 uJ |
| Operating mode / pulse width | Pulsed | 100 Hz-10 kHz | 100 Hz-10 kHz |
| Beam quality | <3 | Confirm for this model | ≤3 |
Compare the DPS-213-Pico with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide