Power, wavelength, beam profile, safety
Laser Wavelength Measurement
- Aurora4000 series: Features: High resolution: can be up to 0.1 nm(FWHM); Resolution: 0.75nm; Wavelength Range: 200-1100nm (custom design); Description: Able to measure wavelength, line width of laser, LED and other common light source, and also the laser excitation fluorescence, LIBS spectral characteristics.
- Firefly4000 series: Features: Compact: small and portable type; Resolution: 1.01 nm; Wavelength Range: 350-1000nm / 200-850nm (custom design); Description: Able to measure wavelength, line width of laser, LED and other common light source, and also the laser excitation fluorescence, LIBS spectral characteristics.
- Sunshine series: Features: High sensitivity: can be up to 80% quantum efficiency; Resolution: 0.87; Wavelength Range: 200-1100nm (custom design); Description: The laser excitation fluorescence.Able to measure laser excitation Raman spectral characteristics.
- Metal series: Features: High signal-to-noise ratio; Resolution: 0.87; Wavelength Range: 200-1100nm (custom design); Description: The laser excitation fluorescence.Able to measure laser excitation Raman spectral characteristics.
- Wood series: Features: High signal-to-noise ratio; Resolution: 6.5nm; Wavelength Range: 900 -1700nm; Description: Able to measure wavelength, line width of laser, LED and other common light source, and also the laser excitation fluorescence
- Wood series: Features: High signal-to-noise ratio; Resolution: 15nm; Wavelength Range: 1000-2500nm; Description: Able to measure wavelength, line width of laser, LED and other common light source, and also the laser excitation fluorescence

Fibre-optic spectrometers
Choose your wavelength measurement spectrometer
Compare models for laser wavelength and linewidth measurements, weak signals, near-infrared detection and synchronised acquisition. Each model opens its full spectroscopy product page in a new tab, with specifications, configuration options, drawings and available documents.

High resolution
Aurora 4000
Laser wavelength and linewidth analysis, LED sorting and any measurement where resolution matters more than sensitivity.
- Resolution, up to (FWHM)
- 0.1 nm
- Detector range
- 200–1100 nm

High sensitivity
Sunshine
Raman, fluorescence and LIBS spectra, semiconductor processing, life science and gas analysis.
- Quantum efficiency, up to
- 80 %
- Detector range
- 200–1100 nm

Compact
Firefly 4000
Teaching, field use and OEM integration where size and weight decide, and 1 nm resolution is enough.
- Weight
- 170 g
- Footprint
- 89 × 64 × 32 mm

TE-cooled, back-illuminated CCD
Metal
Weak Raman and fluorescence signals, long integrations, and UV work where a back-illuminated sensor pays off.
- Below ambient, TE-cooled
- −20 °C
- Maximum integration
- 60 s

Near-infrared, InGaAs
Wood
NIR absorption and moisture analysis, fruit and crop testing, telecom laser wavelengths, and on-line composition or concentration monitoring.
- Two ranges
- 900–2500 nm
- Signal-to-noise
- 1200:1

Multi-channel, synchronised
Rainbow multi-channel
LIBS and plasma spectroscopy, where a wide spectral window has to be captured at high resolution in a single, precisely timed shot.
- Synchronised channels
- 2–6
- Resolution, up to
- 0.1 nm
Compare the full spectroscopy range
View the comparison table, Raman and fluorescence probes, complete systems and accessories.
Explore fibre-optic spectrometers(opens in a new tab)Opens in a new tab.
Need this configured?
Share wavelength range, measurement target, detector needs, sample geometry, software and interface requirements, and we will qualify the matching configuration.