Spectroscopy Detectors · Mid-infrared single-point detectors

DMCT Series

DMCT Liquid-Nitrogen-Cooled MCT Detectors

  • Models: DMCT12-De01 / DMCT14-De01 / DMCT16-De01 / DMCT22-De01 / DMCT12-HS
  • Active area: 1 × 1 mm
  • Spectral ranges: 2–12 / 2–14 / 2–16 / 2–22 µm, model dependent
  • High-speed rise time: DMCT12-HS: < 50 ns
  • Preamplifier: Optional or integrated, model dependent
  • Cooling: Liquid nitrogen
View quote list

Product range

Where DMCT Series fits

  • Category: Spectroscopy Detectors
  • Family: Mid-infrared single-point detectors

Specifications

ModelsDMCT12-De01 / DMCT14-De01 / DMCT16-De01 / DMCT22-De01 / DMCT12-HS
Active area1 × 1 mm
Spectral ranges2–12 / 2–14 / 2–16 / 2–22 µm, model dependent
High-speed rise timeDMCT12-HS: < 50 ns
PreamplifierOptional or integrated, model dependent
CoolingLiquid nitrogen

Construction details

  • Cooling assembly: Liquid nitrogen.

Product comparison

Check a reference product

Considering DMCT Series for an existing setup? Send us the reference product number and your required specifications. Our engineers can help check the function, configuration, dimensions and interfaces.

Ask our engineers →

Complete source specification

Model-by-model comparison

The full manufacturer-published comparison is transcribed below so model differences remain visible rather than being reduced to a single range.

ParameterDMCT12-De01DMCT14-De01DMCT16-De01DMCT22-De01DMCT12-HS
Active area1 × 1 mm1 × 1 mm1 × 1 mm1 × 1 mm1 × 1 mm
Spectral range2–12 µm2–14 µm2–16 µm2–22 µm2–12 µm
Peak responsivity3 × 10³ V/W1 × 10³ V/W900 V/W150 V/W> 4 × 10⁴ V/W
Rise time————< 50 ns
D* at peak, 1 kHz, minimum3 × 10¹⁰3 × 10¹⁰2.5 × 10¹⁰5 × 10⁹3 × 10¹⁰
PreamplifierOptionalOptionalOptionalOptionalIntegrated
Signal outputVoltageVoltageVoltageVoltageVoltage
Output polarityPPPPP

Design and integration details

  • Liquid-nitrogen-cooled MCT detector family with cut-offs from 12 to 22 µm.
  • Routine De01 models accept an optional preamplifier; the high-speed model integrates one.
  • DMCT12-HS uses a 20 MHz preamplifier for time-resolved measurements and direct oscilloscope connection.

Application and connection notes

  • Routine DMCT(x)-De heads require a preamplifier and lock-in amplifier when supplied without the -PA option.
  • DMCT12/14/16/22-De01-PA variants include the original preamplifier.
  • The source states that one liquid-nitrogen fill can maintain operation for approximately eight hours.
  • Standard configuration is for a manual Omni-λ slit; contact us for motorized-slit integration.

Values are transcribed from the archived product table and diagrams. Confirm the final detector, electronics and spectrograph interface for your configuration.

System integration

Integration and compatibility

  • Spectral response: Spectral ranges: 2–12 / 2–14 / 2–16 / 2–22 µm, model dependent
  • Active area: Active area: 1 × 1 mm
  • Noise and cooling: Cooling: Liquid nitrogen
  • Output and bias: Preamplifier: Optional or integrated, model dependent

Technical FAQ

Integration questions for DMCT Series

What wavelengths does the DMCT Series detect?
  • Spectral ranges: 2–12 / 2–14 / 2–16 / 2–22 µm, model dependent. Responsivity varies strongly across the stated band. Read the figure at your own wavelength rather than at the peak the headline range implies.
What is the active area of the DMCT Series?
  • Active area: 1 × 1 mm. Active area sets both the alignment tolerance and, through capacitance, the achievable bandwidth. A larger element is easier to hit and slower to read.
What is the noise floor of the DMCT Series?
  • Cooling: Liquid nitrogen. Compare NEP or dark current at the operating temperature and bandwidth you will actually use; both figures improve with cooling and degrade with bandwidth, so a single number without conditions is not comparable.
How is the DMCT Series read out?
  • Preamplifier: Optional or integrated, model dependent. Confirm whether the module is biased and amplified internally or expects an external supply and transimpedance stage. The two builds are not interchangeable and the wrong assumption destroys detectors.

Model selection

Nearby series comparison

Compare DMCT Series with the closest available models in the Mid-infrared single-point detectors family.

Selection parameterDMCT Series (current)DInSb5 SeriesDPbS Series
Spectral response2–12 / 2–14 / 2–16 / 2–22 µm, model dependent1–5.5 µm0.8–2.9 µm / 0.8–3.2 µm
Active area1 × 1 mmØ2 mm / 1 × 1 mm4 × 5 mm / 6 × 6 mm
Cooling / outputLiquid nitrogenLiquid nitrogenVoltage