Back to Home
AUS25.4

Kinematic Mirror Mount · AUS series Kinematic Mirror Mounts

AUS25.4

AUS series Kinematic Mirror Mounts

Premium aluminium alloy, with black anodic oxidation; By adopting a superior line-line-line structure to replace the traditional point-line-surface structure, this mount offers significantly higher adjustment accuracy; Thicker mounting plate provides better ri

View quote list
Datasheet (PDF) ↗CAD Model (RAR) ↗

Catalog context

Where AUS25.4 fits

AUS25.4 is listed as AUS series Kinematic Mirror Mounts in the AUS series Kinematic Mirror Mounts family. The local catalog record provides these first selection fields: Optic Size (mm): φ25/ φ25.4; Optics Thickness (mm): 3~6; Adjustment Angle Range (°): ±3.

Specifications

Optic Size (mm)φ25/ φ25.4
Optics Thickness (mm)3~6
Adjustment Angle Range (°)±3
Front Plate Translation (mm)MAX6
Clear Aperture (mm)φ24
Optic Center Height (mm)25
Resolution: angular adjustment per revolution(°)≈0.33
Main Body Material and TreatmentAluminium alloy, surface treated by black anodic oxidation.
Thickness of The Fixed Plate(mm)16
Number of Pulling Spring4
Locking MechanicsYes
Mounting HoleM4 M6,φ8 sink hole
Net Weight(g)130

Application context

Why this design is used

Application guidance is derived from the product family and tied to the model-specific selection fields above.

Beam steering

Two-axis angular adjustment for directing a beam between components on the table.

Cavity and interferometer alignment

Hold pointing where a few microradians of drift is visible directly in the measurement.

Repeatable optic exchange

Kinematic seating returns an optic to the same orientation after it has been removed.

System integration

Integration and compatibility

Use these checks to connect AUS25.4 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Optic it accepts
Optic Size (mm): φ25/ φ25.4 · Optics Thickness (mm): 3~6
Check diameter and thickness together. A holder that accepts the diameter can still fail to retain an optic that is thinner than its minimum, and clear aperture is normally smaller than the optic the mount holds.
Mounting interface
Mounting Hole: M4 M6,φ8 sink hole
Match the thread standard and hole pitch before ordering. Metric and imperial hardware interchange only through an adapter, and a thread that is nominally similar is not necessarily the same pitch.
Adjustment
Adjustment Angle Range (°): ±3 · Resolution: angular adjustment per revolution(°): ≈0.33
Adjuster pitch sets the sensitivity you can actually work at. Confirm whether the stated figure is a total range or a per-revolution increment, and whether the mechanism is locked after adjustment.
Material and finish
Main Body Material and Treatment: Aluminium alloy, surface treated by black anodic oxidation.
Aluminium moves about 23 ppm per kelvin and stainless about 16. In a path where thermal drift is already budgeted, the material of the mount belongs in that budget rather than in the appearance of the part.
Dimensions and mass
Net Weight(g): 130
Use the stated geometry and mass to fix beam height, clearance and the load carried by whatever this part is bolted to. These are the numbers that decide whether adjacent components physically collide.

Technical FAQ

Integration questions for AUS25.4

Which optics fit the AUS25.4?

Optic Size (mm): φ25/ φ25.4 · Optics Thickness (mm): 3~6. Check diameter and thickness together. A holder that accepts the diameter can still fail to retain an optic that is thinner than its minimum, and clear aperture is normally smaller than the optic the mount holds.

How does the AUS25.4 mount?

Mounting Hole: M4 M6,φ8 sink hole. Match the thread standard and hole pitch before ordering. Metric and imperial hardware interchange only through an adapter, and a thread that is nominally similar is not necessarily the same pitch.

What adjustment range does the AUS25.4 offer?

Adjustment Angle Range (°): ±3 · Resolution: angular adjustment per revolution(°): ≈0.33. Adjuster pitch sets the sensitivity you can actually work at. Confirm whether the stated figure is a total range or a per-revolution increment, and whether the mechanism is locked after adjustment.

What is the AUS25.4 made from?

Main Body Material and Treatment: Aluminium alloy, surface treated by black anodic oxidation.. Aluminium moves about 23 ppm per kelvin and stainless about 16. In a path where thermal drift is already budgeted, the material of the mount belongs in that budget rather than in the appearance of the part.

What are the dimensions of the AUS25.4?

Net Weight(g): 130. Use the stated geometry and mass to fix beam height, clearance and the load carried by whatever this part is bolted to. These are the numbers that decide whether adjacent components physically collide.

Model selection

Nearby series comparison

Compare AUS25.4 with the closest available models in the AUS series Kinematic Mirror Mounts family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterAUS25.4 (current)AUS20AUS38.1
Optic acceptedφ25/ φ25.4φ20φ38.1
Adjustment±3±3±3
Mounting interfaceM4 M6,φ8 sink holeM4 M6,φ8 sink holeM4 M6,φ8 sink hole
MaterialAluminium alloy, surface treated by black anodic oxidation.Aluminium alloy, surface treated by black anodic oxidation.Aluminium alloy, surface treated by black anodic oxidation.