Opto-Mechanics · UFP series High Sensitivity Manual Stages
UFP2T-L high-sensitivity two-axis tilt stage
Two-axis angular positioner for aligning fiber end faces, lenses, and compact photonic assemblies. Crossed-roller-ring guidance provides fine, stable pitch and yaw adjustment.
Datasheet (PDF) ↗CAD Model (RAR) ↗Catalog context
UFP2T-L is listed as UFP2T-L high-sensitivity two-axis tilt stage in the UFP series High Sensitivity Manual Stages family. The local catalog record provides these first selection fields: Stage surface size(mm): 45×45; Travel range: θx:±3°;θy:±3°; Guide mechanism: Crossed-roller ring.
| Stage surface size(mm) | 45×45 |
|---|---|
| Travel range | θx:±3°;θy:±3° |
| Guide mechanism | Crossed-roller ring |
| Drive type | Micrometer |
| Main body material and surface | Black anodized aluminum alloy |
| Weight(Kg) | 0.64 |
| Sensitivity | θx:≤25.2” ;0y; ≤234 |
| Static parallelism | ≤60µm |
| Motion parallelism | ≤10µm |
| Motion straightness | ≤3µm |
| Horizontal direction(Kg) | 1.5 |
Application context
Application guidance is derived from the product family and tied to the model-specific selection fields above.
Adjust once during setup and lock, on axes that do not need to move again during the run.
Establish the optical axis by hand before a piezo or motorised stage takes the fine motion.
Reconfigure a layout quickly, with no cabling, controllers or electrical noise added to the experiment.
System integration
Use these checks to connect UFP2T-L to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Travel range: θx:±3°;θy:±3° · Sensitivity: θx:≤25.2” ;0y; ≤234. Adjuster pitch sets the sensitivity you can actually work at. Confirm whether the stated figure is a total range or a per-revolution increment, and whether the mechanism is locked after adjustment.
Stage surface size(mm): 45×45 · Main body material and surface: Black anodized aluminum alloy. Aluminium moves about 23 ppm per kelvin and stainless about 16. In a path where thermal drift is already budgeted, the material of the mount belongs in that budget rather than in the appearance of the part.
Weight(Kg): 0.64. Use the stated geometry and mass to fix beam height, clearance and the load carried by whatever this part is bolted to. These are the numbers that decide whether adjacent components physically collide.
Model selection
Compare UFP2T-L with the closest available models in the UFP series High Sensitivity Manual Stages family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | UFP2T-L (current) | UFP1C-R | UFP2T-R |
|---|---|---|---|
| Optic accepted | Confirm for this model | Confirm for this model | Confirm for this model |
| Adjustment | θx:±3°;θy:±3° | coarse tuning:±6.5mm;fine tuning:±±0.3mm | θx:±3°;θy:±3° |
| Mounting interface | Confirm for this model | Confirm for this model | Confirm for this model |
| Material | 45×45 | 60×60 | 45×45 |
Before you specify
Engineering context for choosing this class of component, with the tradeoffs worked through on real specifications.
Precision motionTranslate temperature, pressure, travel, payload, feedback, and motion requirements into a defensible cryogenic-stage shortlist.
Open guide
Opto-mechanicsVibration, thermal drift and mechanical integration are one problem. Budget the motion at the sample, then specify the table, the isolation, the mounts and the beam height that budget asks for.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide