Back to Home
LAK20-60 Motorized Linear Stage

Zolix · Motorized Stages

LAK20-60 Motorized Linear Stage

Motorized linear stage with 20 mm travel and a 60×60 mm table. Transmission: imported C3 ball screw φ6×1; guide: linear-slider guides. Repositioning accuracy ≤±1 µm; max speed 20 mm/s. Horizontal load capacity 8 kg; weight 0.58 kg.

Travel range
20 mm
Repositioning accuracy
≤±1 µm
Horizontal load capacity
8 kg
Table size
60×60 mm
View quote list
LAK Series Submicron Motorized Linear Stages

Specifications

Mechanical

Travel range (mm)20
Table size (mm)60×60
Transmission mechanismImported C3 ball screw φ6×1
Guide mechanismLinear-slider guides
Body material and finishBlack anodized aluminum alloy
Weight (kg)0.58
Shaft coupling, OD-bore-bore (mm)16-3-5
Up-and-down swing (N·m)9.31
Left-and-right swing (N·m)9.8
Axial rotation (N·m)9.31
Up-and-down swing (µm/90 N·cm)≤6
Left-and-right swing (µm/90 N·cm)≤6

Accuracy

Resolution, full/half step (µm)2/1
Resolution, 20× microstep (µm)0.1
Max speed (mm/s)20
Single-direction positioning accuracy (µm)≤20
Repositioning accuracy (µm)≤±1
Backlash (µm)≤1
Static parallelism (mm)≤0.05
Dynamic straightness (µm)≤10
Dynamic parallelism (µm)≤10
Yaw (arcsec)≤25
Pitch (arcsec)≤30
Minimum incremental motion (µm)≤1

Motor & electrical

Motor and step angle (°)Five-phase 28 stepping motor,0.72
Motor modelOriental Motor, PKP523N12B-L
Motor current (A)1.2
Motor holding torque (N·m)52.5
Stepper driver (optional)Oriental Motor, CVD512BR-K

Sensors & connection

Connector10pin connector
Cable typeHigh flexibility cable
Cable length (m)0.2
Limit sensors (built-in)2×EE-SX4320 (OMRON, Japan)
Origin sensor (built-in)1×EE-SX4320 (OMRON, Japan)
Sensor supply voltageDC5~24V±10%
Sensor outputNPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Sensor output logicOutput OFF when sensor is blocked

Load capacity

Horizontal load capacity (kg)8
Vertical load capacity (kg)3
Inverted load capacity (kg)4

Compatible controllers

For the five-phase 28 stepping motor this stage uses.