Rainbow multi-channel
Rainbow Series Multi-Channel Spectrometer
Two to six Aurora-class 3648-pixel spectrometers in one housing, each covering a slice of the spectrum, with a synchronous delay device that fires all channels together. Wide range and high resolution at once — 185–930 nm at 0.08–0.22 nm in the standard configurations — with internal or external triggering for pulsed sources.
2–6
Synchronised channels
0.1 nm
Resolution, up to
< 1 ns
Delay jitter
0–1 ms
Delay control range

Features
- High resolution across a wide spectral range
- Number of channels and their spectral ranges customised to the application
- Built-in synchronous delay device for simultaneous acquisition on every channel
- Internal or external control (trigger) mode
- Works with the Spectral Analysis and LIBS software
Applications
- Plasma spectral analysis
- Laser-induced breakdown spectroscopy (LIBS)
- Soil pollution analysis
- Heavy-metal analysis
- Food safety analysis
- Biological analysis
Available Models
Ordering Options
Standard channel layouts; other channel counts and ranges are configured to order.
Rainbow 2-channel
200–550 nm overall: 200–340 nm at 0.14 nm, 340–550 nm at 0.2 nm
Rainbow 3-channel
250–645 nm overall: 250–346, 346–440 and 440–645 nm at 0.12 / 0.12 / 0.18 nm
Rainbow 4-channel
190–930 nm overall: 190–320, 320–520, 520–700 and 700–930 nm at 0.14 / 0.18 / 0.18 / 0.22 nm
Rainbow 5-channel
185–530 nm overall: 185–240, 240–280, 280–370, 370–455 and 455–530 nm at 0.08 / 0.08 / 0.11 / 0.11 / 0.11 nm
Standard channel configurations
Wavelength range and optical resolution (nm) per channel.
| Configuration | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 |
|---|---|---|---|---|---|
| 2 channels (200–550 nm) | 200–340 nm · 0.14 | 340–550 nm · 0.2 | — | — | — |
| 3 channels (250–645 nm) | 250–346 nm · 0.12 | 346–440 nm · 0.12 | 440–645 nm · 0.18 | — | — |
| 4 channels (190–930 nm) | 190–320 nm · 0.14 | 320–520 nm · 0.18 | 520–700 nm · 0.18 | 700–930 nm · 0.22 | — |
| 5 channels (185–530 nm) | 185–240 nm · 0.08 | 240–280 nm · 0.08 | 280–370 nm · 0.11 | 370–455 nm · 0.11 | 455–530 nm · 0.11 |
Technical Specifications
Rainbow multi-channel Specifications
Spectrometer (per channel)
| Wavelength range | 185–1200 nm overall; band and resolution per channel customised to order |
|---|---|
| Optical resolution | < 0.75 nm FWHM; down to 0.08 nm in the standard channel layouts |
| Pixels | 3648 |
| Pixel size | 8 µm × 200 µm |
| Signal-to-noise ratio | 300:1 |
| Integration time | 4 ms – 10 s |
| Power consumption | 450 mA at 5 V DC per spectrometer |
Delay device
| Synchronous channels | 6 (other channel counts to suit the spectrometer) |
|---|---|
| Trigger mode | Internal or external control |
| Delay jitter | < 1 ns |
| Delay control range | 0–1 ms |
| Signal outputs | 5 V TTL |
Software
| Spectrum analysis | Spectral Analysis / LIBS software |
|---|---|
| Operating system | Windows XP / 7 / 10, 32- or 64-bit |
System
| Dimensions | 155 × 262 × 168 mm (varies with the number of channels) |
|---|---|
| Computer interface | USB 2.0 and USB 1.0 |
| Power supply | 220 V AC, 50–60 Hz |
| Fibre connector | SMA905 or FC; multi-in-one fibre bundle to match the channel count |
| Warranty | 1 year |
Final specifications depend on the configured wavelength range, entrance aperture and grating. We confirm the configuration before quotation.