Power stability, linewidth, beam quality
MLL-V-671-SM671 nm red CW laser
671 nmMLL-V-671-SM is a 671 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. Laser. Key specifications: output / average power 250~3000 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <3%, <2%, (<1% optional). View specifications, datasheet and enquiry options from Precisometer.
Specifications
MLL-V-671-SM
22 specification rows
| Output / average power | 250~3000 mW |
|---|---|
| Beam / notes | Laser |
| Operating mode | CW |
| Power Stability (rms, 4 hours ± 3°C) | <3%, <2%, (<1% optional) |
| Transverse mode | TEM00 (single mode fiber output) |
| M2 | <1.1 |
| Polarization ratio (optional) | >50:1 after PM fiber |
| Noise of amplitude (rms, 20Hz-20MHz) | <1% |
| Fiber type | SM fiber (PM fiber optional) |
| Fiber core diameter | 4um,0.10NA |
| Fiber connector | FC/APC |
| Fiber length | 1m |
| Fiber Jacket | PVC, Metal optional |
| Warm-up time (minutes) | <10 |
| Cooled method | Air Cooled (Water Cooled optional) |
| Operating temperature (°C) | 10-30 |
| Power supply (100-240VAC) | PSU-W-LED |
| Modulation option | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 671±1 |
| Output power (mW) | 250-3000 |
| M² | <1.1 |
Applications
Typical uses for lasers of this wavelength and type in this catalogue.
- Flow cytometry
- DNA sequencing
- Medical imaging
- Collimation
- Laser medical treatment
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Related cw lasers
Compare the MLL-V-671-SM with nearby cw lasers across the wavelength range.