MLL-V-671-SM is a 671 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. Laser. Key specifications: output / average power 250~3000 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <3%, <2%, (<1% optional). View specifications, datasheet and enquiry options from Precisometer.
DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional
Expected lifetime (hours)
>10000
Wavelength (nm)
671±1
Output power (mW)
250-3000
M²
<1.1
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
MLL-V-671-SM: 671 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<3%, <2%, (<1% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
MLL-V-671-SM: 671 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%, (<1% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.
Medical imaging
MLL-V-671-SM: 671 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<3%, <2%, (<1% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.
Collimation
MLL-V-671-SM: Collimation benefits from a stable, focusable source. 671 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00 (single mode fiber output)) informs waist size and propagation.
System integration
Integration and compatibility
Use these checks to connect MLL-V-671-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Air Cooled (Water Cooled optional) · Operating temperature (°C): 10-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MLL-V-671-SM
How is the MLL-V-671-SM output delivered?+
Fiber type: SM fiber (PM fiber optional) · Fiber core diameter: 4um,0.10NA. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
What cooling does the MLL-V-671-SM require?+
Cooled method: Air Cooled (Water Cooled optional) · Operating temperature (°C): 10-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MLL-V-671-SM deliver?+
Transverse mode: TEM00 (single mode fiber output) · M2: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MLL-V-671-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.