MLL-V-671 is a 671 nm CW laser. Used for dna sequencing, flow cytometry, cell sorting, optical instrument. Laser. Key specifications: output / average power 1.5~5 W, operating mode CW, power stability (rms, 4 hours ± 3°c) <3%, <2%, (<1% optional). View specifications, datasheet and enquiry options from Precisometer.
Pointing Stability(urad) (over 2 hours after warm-up and ±3°C)
<50
Beam height from base plate (mm)
68
Cooled method
Water Cooled
Modulation option
DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional
Application context
Why this design is used
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
DNA sequencing
MLL-V-671: 671 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%, (<1% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.
Flow cytometry
MLL-V-671: 671 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<3%, <2%, (<1% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.
Cell sorting
MLL-V-671: 671 nm emission determines compatible optics, coatings and detectors for Cell sorting. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
Optical instrument
MLL-V-671: 671 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect MLL-V-671 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Operating temperature (°C): 10-35 · Cooled method: Water Cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.3
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MLL-V-671
What cooling does the MLL-V-671 require?+
Operating temperature (°C): 10-35 · Cooled method: Water Cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MLL-V-671 deliver?+
Transverse mode: TEM00 · M2: <1.3. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MLL-V-671 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.