Back to Home

Pulse energy, repetition rate, pulse width

AO-355W355 nm UV Q-switched pulsed laser

355 nm

AO-355W is a 355 nm Pulsed laser. Used for scientific research, biology, instrumentation. Key specifications: output / average power 5 W, pulse energy 1 mJ, repetition rate 1 Hz-200 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

AO-355W

18 specification rows

Output / average power5 W
Pulse energy1 mJ
Repetition rate1 Hz-200 kHz
Pulse width~15 ns @5 kHz
Operating modeAcousto-Optic Q-switched
Power stability (rms, 4 hours ± 3°C)<2%, <1%
Transverse modeTEM00
Beam divergence, full angle (mrad)<3.5
M2<1.2
Polarization ratio>100:1 Horizontal
Warm-up time (minutes)<10
Cooled methodWater cooled
Operating temperature (℃)10-35
Operating voltage (VDC)24V/20.9A (AO-355W-I) / 12V/25A (AO-355W-II)
Expected lifetime (hours)>10000
Wavelength (nm)355±1
Beam diameter at the aperture (1/e2, mm)~0.8
<1.2

Applications

Uses named on this model’s datasheet.

  • Scientific research
  • Biology
  • Instrumentation

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector