Back to Home

Power stability, linewidth, beam quality

TUN-W-2600~44103000 nm infrared tunable CW laser

3000 nm

TUN-W-2600~4410 is a 3000 nm CW laser. Used for spectroscopy, remote sensing, medical. Tunable Mid-Infrared Laser. Key specifications: output / average power 250~1000 mW, operating mode CW, power stability (rms, 4 hours±3℃) <5%, <3%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

TUN-W-2600~4410

9 specification rows

Wavelength3000 nm
Output / average power250~1000 mW
Beam / notesTunable Mid-Infrared Laser
Operating modeCW
Power stability (rms, 4 hours±3℃)<5%, <3%
Beam divergence, full angle (mrad)<11
Cooled methodAir Cooled
Operating temperature (℃)15-35
Power supply (100-240VAC)RAD1PS
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Spectroscopy

TUN-W-2600~4410: 3000 nm emission sets the excitation and detector-band choice for Spectroscopy; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<11) also controls focusing and collection geometry.

Remote sensing

TUN-W-2600~4410: 3000 nm emission determines compatible optics, coatings and detectors for Remote sensing. The catalogued beam parameter (<11) helps predict how the source will focus and propagate through the instrument.

Medical

TUN-W-2600~4410: 3000 nm emission determines compatible optics, coatings and detectors for Medical. The catalogued beam parameter (<11) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect TUN-W-2600~4410 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air Cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <11
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for TUN-W-2600~4410

What cooling does the TUN-W-2600~4410 require?

Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the TUN-W-2600~4410 deliver?

Beam divergence, full angle (mrad): <11. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare TUN-W-2600~4410 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterTUN-W-2600~4410 (current)MIL-V-3000MIL-W-3000
Wavelength3000 nm3000 nm3000 nm
Optical power / pulse energy250~1000 mW1~400 mW250~1000 mW
Operating mode / pulse widthCWCWCW
Beam quality<11<5<11