TUN-W-2600~4410 is a 2921 nm CW laser. Used for spectroscopy, remote sensing, medical. Laser. Key specifications: output / average power 250~1000 mW, operating mode CW, power stability (rms, 4 hours±3℃) <5%, <3%. View specifications, datasheet and enquiry options from Precisometer.
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
Spectroscopy
TUN-W-2600~4410: 2921 nm emission sets the excitation and detector-band choice for Spectroscopy; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<11) also controls focusing and collection geometry.
Remote sensing
TUN-W-2600~4410: 2921 nm emission determines compatible optics, coatings and detectors for Remote sensing. The catalogued beam parameter (<11) helps predict how the source will focus and propagate through the instrument.
Medical
TUN-W-2600~4410: 2921 nm emission determines compatible optics, coatings and detectors for Medical. The catalogued beam parameter (<11) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect TUN-W-2600~4410 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method: Air Cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <11
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for TUN-W-2600~4410
What cooling does the TUN-W-2600~4410 require?+
Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the TUN-W-2600~4410 deliver?+
Beam divergence, full angle (mrad): <11. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare TUN-W-2600~4410 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.