A drill
MIL-W-2921: 2921 nm emission determines compatible optics, coatings and detectors for A drill. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.
Power stability, linewidth, beam quality
MIL-W-2921 is a 2921 nm CW laser. Used for a drill. Laser. Key specifications: output / average power 10~900 mW, operating mode CW, power stability (rms, 4 hours±3℃) <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
15 specification rows
| Output / average power | 10~900 mW |
|---|---|
| Beam / notes | Laser |
| Operating mode | CW |
| Power stability (rms, 4 hours±3℃) | <2%, <1% |
| Transverse mode | Near TEM00 |
| Beam divergence, full angle (mrad) | <4 |
| Warm-up time (minutes) | <10 |
| Cooled method | Air Cooled |
| Operating temperature (℃) | 15-35 |
| Power supply (100-240VAC) | PSU-H-LED |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 2921±3 |
| Output power (mW) | 10-900 |
| Beam diameter at the aperture (1/e2,mm) | <5 |
| Beam height from base plate (mm) | 98 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
MIL-W-2921: 2921 nm emission determines compatible optics, coatings and detectors for A drill. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect MIL-W-2921 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: Near TEM00 · Beam divergence, full angle (mrad): <4. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MIL-W-2921 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MIL-W-2921 (current) | TUN-W-2600~4410 | MIL-W-2910 |
|---|---|---|---|
| Wavelength | 2921 nm | 2921 nm | 2910 nm |
| Optical power / pulse energy | 10~900 mW | 250~1000 mW | 250~1000 mW |
| Operating mode / pulse width | CW | CW | CW |
| Beam quality | Near TEM00 | <11 | <11 |
Compare the MIL-W-2921 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide