Lidar
PS-M-560: Lidar depends on how optical energy is delivered to the target; 560 nm emission governs absorption, while pulse energy, duration and repetition rate governs peak intensity and heat deposition.
Pulse energy, repetition rate, pulse width
PS-M-560 is a 560 nm Pulsed laser. Used for lidar, laser spectroscopy, sensing, metrology. Picosecond Pulsed Yellow Green Laser. Key specifications: output / average power 1~800 mW, operating mode Passively Q-switched, rep. rate (khz) 500-1000. View specifications, datasheet and enquiry options from Precisometer.
Specifications
12 specification rows
| Wavelength | 560 nm |
|---|---|
| Output / average power | 1~800 mW |
| Beam / notes | Picosecond Pulsed Yellow Green Laser |
| Operating mode | Passively Q-switched |
| Rep. rate (kHz) | 500-1000 |
| Power stability (rms, over 4 hours) | <3%, (<2% optional) |
| Beam divergence, full angle (mrad) | <1 |
| Beam diameter at the aperture (1/e2,mm) | ~3.0 |
| Beam height from base plate (mm) | 116 |
| Cooled method | Water cooled |
| Operating temperature (℃) | 15~35 |
| Power supply (220/110VAC) | On request |
| Expected lifetime (hours) | 10000 |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
PS-M-560: Lidar depends on how optical energy is delivered to the target; 560 nm emission governs absorption, while pulse energy, duration and repetition rate governs peak intensity and heat deposition.
PS-M-560: 560 nm emission sets the excitation and detector-band choice for Laser spectroscopy; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<1) also controls focusing and collection geometry.
PS-M-560: 560 nm emission determines compatible optics, coatings and detectors for Sensing. The catalogued beam parameter (<1) helps predict how the source will focus and propagate through the instrument.
PS-M-560: 560 nm emission determines compatible optics, coatings and detectors for Metrology. The catalogued beam parameter (<1) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect PS-M-560 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Water cooled · Operating temperature (℃): 15~35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam divergence, full angle (mrad): <1 · Beam diameter at the aperture (1/e2,mm): ~3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare PS-M-560 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
Compare the PS-M-560 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.