Scientific research
PS-M-330: 330 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
Pulse energy, repetition rate, pulse width
PS-M-330 is a 330 nm Pulsed laser. Used for scientific research, icp-ms, laser processing, measure. Picosecond Pulsed UV Laser. Key specifications: output / average power 1~30 mW, operating mode Passively Q-switched, rep. rate (khz) 500-1000. View specifications, datasheet and enquiry options from Precisometer.
Specifications
15 specification rows
| Output / average power | 1~30 mW |
|---|---|
| Beam / notes | Picosecond Pulsed UV Laser |
| Operating mode | Passively Q-switched |
| Rep. rate (kHz) | 500-1000 |
| Power stability (rms, over 4 hours) | <3%, (<2% optional) |
| Beam diameter at the aperture (1/e2,mm) | ~3.0 |
| Cooled method | Water cooled |
| Operating temperature (℃) | 15~35 |
| Power supply (220/110VAC) | On request |
| Wavelength (nm) | 330±1 |
| Average power (W) | 1-30mW (30mW@1MHz) |
| Single pulse energy (nJ) | 1-30nJ(30nJ @1MHz) |
| Pulse duration (ps) | 10ps@1MHz,30mW |
| Peak power (kW) | 3kW @1MHz |
| Beam height from base plate (mm) | 116 |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
PS-M-330: 330 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
PS-M-330: 330 nm emission determines compatible optics, coatings and detectors for ICP-MS. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
PS-M-330: Laser processing depends on how optical energy is delivered to the target; 330 nm emission governs absorption, while the listed temporal parameter (1-30nJ(30nJ @1MHz)) governs peak intensity and heat deposition.
PS-M-330: Measure benefits from a stable, focusable source. 330 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
System integration
Use these checks to connect PS-M-330 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Water cooled · Operating temperature (℃): 15~35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam diameter at the aperture (1/e2,mm): ~3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare PS-M-330 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | PS-M-330 (current) | PS-L-330 | AO-U-320-DP |
|---|---|---|---|
| Wavelength | 330 nm | 330 nm | 320 nm |
| Optical power / pulse energy | 1~30 mW | 1~10 mW | 1~40 mW |
| Operating mode / pulse width | Passively Q-switched | <500 | 1-30 kHz |
| Beam quality | Confirm for this model | Confirm for this model | <2.0 |
Compare the PS-M-330 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.