Back to Home

Pulse energy, repetition rate, pulse width

MPL-N-343343 nm UV Q-switched pulsed laser

343 nm

MPL-N-343 is a 343 nm Pulsed laser. Passively Q-switched UV Laser. Key specifications: operating mode Passively Q-switched, output / average power 1~50 mW, pulse energy 0.1~7 uJ. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MPL-N-343

20 specification rows

Operating modePassively Q-switched
Output / average power1~50 mW
Pulse energy0.1~7 uJ
Beam / notesPassively Q-switched UV Laser
Pulse duration (ns)~7
Ave power stability (over 4 hours)<5%, <3%
Transverse modeNear TEM00
Beam diameter at the aperture (mm)~1.0
Polarization ratio>50:1, Horizontal (Vertical optional)
Warm-up time (minutes)<5
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-Q-FDA/PSU-Q-LED
Expected lifetime (hours)>10000
Wavelength (nm)343±1
Max average power (mW)1-50
Single pulse energy (µJ)0.1-7
Peak power (kW)0.01-1
Rep. rate (kHz)4-8
<2.0
Beam height from base plate (mm)70

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

MPL-N-343: 343 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

MPL-N-343: Laboratory measurement benefits from a stable, focusable source. 343 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (Near TEM00) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect MPL-N-343 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam diameter at the aperture (mm): ~1.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MPL-N-343

What cooling does the MPL-N-343 require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MPL-N-343 deliver?

Transverse mode: Near TEM00 · Beam diameter at the aperture (mm): ~1.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MPL-N-343 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMPL-N-343 (current)MPL-F-349AO-S-349
Wavelength343 nm349 nm349 nm
Optical power / pulse energy1~50 mW1~30 mW1~15 mW
Operating mode / pulse widthPassively Q-switched1-3 kHz1 Hz-1 kHz
Beam qualityNear TEM00TEM00TEM00