Back to Home

Pulse energy, repetition rate, pulse width

PGL-VI-980980 nm near-infrared pulsed laser

980 nm

PGL-VI-980 is a 980 nm Pulsed laser. Used for scientific research, physics experiment, medical imaging, flow cytometry. Nanosecond Pulsed Infrared Laser. Key specifications: operating mode Pulsed, output / average power 1~100 mW, transverse mode Near TEM00 / Multimode. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-VI-980

13 specification rows

Wavelength980 nm
Operating modePulsed
Output / average power1~100 mW
Beam / notesNanosecond Pulsed Infrared Laser
Transverse modeNear TEM00 / Multimode
Beam divergence, full angle (mrad)<1 / <8
Expected lifetime (hours)10000
Warranty (years)1
Operating voltage(internal PCB)3VDC
ConnectionCable with flying leads
Operating temperature0°C to 40°C
Storage temperature-20°C to 80°C
Humidity< 90 %, non-condensing
Dimensions of internal PCBmm2 / Φ12×50

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Scientific research

PGL-VI-980: 980 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (Near TEM00 / Multimode) helps predict how the source will focus and propagate through the instrument.

Physics experiment

PGL-VI-980: Physics experiment benefits from a stable, focusable source. 980 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (Near TEM00 / Multimode) informs waist size and propagation.

Medical imaging

PGL-VI-980: 980 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

PGL-VI-980: 980 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

System integration

Integration and compatibility

Use these checks to connect PGL-VI-980 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: 0°C to 40°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 / Multimode · Beam divergence, full angle (mrad): <1 / <8
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of internal PCB: mm2 / Φ12×50
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL-VI-980

What cooling does the PGL-VI-980 require?

Operating temperature: 0°C to 40°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-VI-980 deliver?

Transverse mode: Near TEM00 / Multimode · Beam divergence, full angle (mrad): <1 / <8. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL-VI-980 mounted?

Dimensions of internal PCB: mm2 / Φ12×50. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-VI-980 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-VI-980 (current)MDL-NS-980MDL-PS-980
Wavelength980 nm980 nm980 nm
Optical power / pulse energy1~100 mW1~200 mW1~50 mW
Operating mode / pulse widthPulsedPulsedPulsed
Beam qualityNear TEM00 / MultimodeMultimodeMultimode