Pulse energy, repetition rate, pulse width

MDL-NS-980980 nm near-infrared pulsed laser

980 nm

MDL-NS-980 is a 980 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing. Pulse width 10 ns ~10 ms. Key specifications: operating mode Pulsed, output / average power 1~200 mW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-NS-980

16 specification rows

Operating modePulsed
Output / average power1~200 mW
Beam / notesPulse width 10 ns~10 ms
Power stability (rms, 4 hours ± 3°C)<2%, <1%, <0.5%
Transverse modeMultimode
Beam divergence, full angle (mrad)<3.0
Warm-up time (minutes)<5
Cooled methodAir cooled
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-H-FDA/PSU-H-LED
Expected lifetime (hours)>10000
Central wavelength (nm)980±10
Output power (mW)2500-5000
Beam diameter at the aperture (mm)~5×8
Beam height from base plate (mm)29
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical imaging

MDL-NS-980: 980 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MDL-NS-980: 980 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MDL-NS-980: 980 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MDL-NS-980 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Multimode · Beam divergence, full angle (mrad): <3.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MDL-NS-980

What cooling does the MDL-NS-980 require?

Cooled method: Air cooled · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MDL-NS-980 deliver?

Transverse mode: Multimode · Beam divergence, full angle (mrad): <3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-NS-980 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-NS-980 (current)MDL-PS-980FC-OEM-980
Wavelength980 nm980 nm980 nm
Optical power / pulse energy1~200 mW1~50 mW1~1000 mW
Operating mode / pulse widthPulsedPulsedPulsed
Beam qualityMultimodeMultimodeConfirm for this model