Scientific experiment
MRL-U-671: 671 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
Power stability, linewidth, beam quality
MRL-U-671 is a 671 nm CW laser. Used for scientific experiment, medical measurement, spectrum analysis. Laser. Key specifications: output / average power 200~500 mW, operating mode CW, power stability (rms, 4 hours, ±3°c) <2%, <1%, <0.5% / <3%, <2%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
21 specification rows
| Output / average power | 200~500 mW |
|---|---|
| Beam / notes | Laser |
| Operating mode | CW |
| Power stability (rms, 4 hours, ±3°C) | <2%, <1%, <0.5% / <3%, <2% |
| Transverse mode | TEM00 |
| M2 | <1.2 |
| Beam divergence (mrad) | <1.5 |
| Polarization ratio | >100:1, Vertical (Horizontal optional) |
| Warm-up time (minutes) | <5 |
| Pointing stability over temperature (urad/°C) | <8 |
| Operating temperature (°C) | 10-35 |
| Power supply (100-240VAC) | PSU-H-LED/PSU-H-FDA/PSU-SR |
| Operating voltage (VDC) | PSU-SR-OEM(12V/25A) |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 671±1 |
| M² | <1.2 |
| Beam diameter at the aperture (1/e2, mm) | <1.0 |
| Pointing stability (urad) (over 2 hours after warm-up and ±3°C) | <50 |
| Beam height from base plate (mm) | 27.4 |
| Laser head consumption (W) | 15 (typical), <25 (40°C) |
| Modulation optional | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
MRL-U-671: 671 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MRL-U-671: Medical measurement benefits from a stable, focusable source. 671 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
MRL-U-671: 671 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (TEM00) also controls focusing and collection geometry.
System integration
Use these checks to connect MRL-U-671 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · M2: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MRL-U-671 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MRL-U-671 (current) | MLL-U-671 | MLL-FN-671 |
|---|---|---|---|
| Wavelength | 671 nm | 671 nm | 671 nm |
| Optical power / pulse energy | 200~500 mW | 1~500 mW | 500~1000 mW |
| Operating mode / pulse width | CW | CW | CW |
| Beam quality | TEM00 | TEM00 | TEM00 |
Compare the MRL-U-671 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.