Back to Home

Power stability, linewidth, beam quality

MRL-S-671-SM671 nm red CW laser

671 nm

MRL-S-671-SM is a 671 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. Laser. Key specifications: output / average power 1~100 mW, operating mode CW, power stability (rms, 4 hours±3°c) <3%, <2%, <1% / <3%, <2%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MRL-S-671-SM

17 specification rows

Output / average power1~100 mW
Beam / notesLaser
Operating modeCW
Power stability (rms, 4 hours±3°C)<3%, <2%, <1% / <3%, <2%
Transverse modeTEM00 (single mode fiber output)
Fiber numerical aperture0.10-0.12
Fiber typeSM fiber (PM fiber optional)
Fiber connectorFC/APC
Fiber jacketPVC (black)
Polarization (optional)>50:1 after PM fiber
Warm-up time (minutes)<10
Operating temperature (°C)10-35
Power supply (90-264VAC)PSU-III-LED/ PSU-III-FDA
Operating voltage(VDC)PSU-A-F-OEM (5V/5A)
Expected lifetime (hours)>10000
Wavelength (nm)671±1
Modulation optionalDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

MRL-S-671-SM: 671 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<3%, <2%, <1% / <3%, <2%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MRL-S-671-SM: 671 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%, <1% / <3%, <2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

MRL-S-671-SM: 671 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<3%, <2%, <1% / <3%, <2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Collimation

MRL-S-671-SM: Collimation benefits from a stable, focusable source. 671 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00 (single mode fiber output)) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect MRL-S-671-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber type: SM fiber (PM fiber optional) · Fiber connector: FC/APC
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 (single mode fiber output) · Polarization (optional): >50:1 after PM fiber
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MRL-S-671-SM

How is the MRL-S-671-SM output delivered?

Fiber type: SM fiber (PM fiber optional) · Fiber connector: FC/APC. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MRL-S-671-SM require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MRL-S-671-SM deliver?

Transverse mode: TEM00 (single mode fiber output) · Polarization (optional): >50:1 after PM fiber. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MRL-S-671-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMRL-S-671-SM (current)MLL-U-671MLL-FN-671
Wavelength671 nm671 nm671 nm
Optical power / pulse energy1~100 mW1~500 mW500~1000 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00 (single mode fiber output)TEM00TEM00