Collimation
MGL-FN-550: Collimation benefits from a stable, focusable source. 550 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
Fiber output, PM options, seed formats
MGL-FN-550 is a 550 nm Fiber laser. Used for collimation, laser medical treatment, scientific experiment, optical instrument. Fiber laser High Stability Green Laser. Key specifications: output / average power 1~500 mW, operating mode CW, power stability (rms, 4 hours±3℃) <3%, <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
15 specification rows
| Wavelength | 550 nm |
|---|---|
| Output / average power | 1~500 mW |
| Beam / notes | Fiber laser High Stability Green Laser |
| Operating mode | CW |
| Power stability (rms, 4 hours±3℃) | <3%, <2%, <1% |
| Transverse mode | TEM00 |
| Beam divergence, full angle (mrad) | <1.5 |
| Polarization Ratio | >100:1, Vertical (Horizontal Optional) |
| Warm-up time (minutes) | <5 |
| Operating Temperature (°C) | 10-35 |
| Modulation optional | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional |
| Power supply (100-240VAC) | PSU-H-FDA/PSU-H-LED/PSU-SR |
| Expected lifetime (hours) | >10000 |
| Pointing Stability(μrad) (over 2 hours after warm-up and ±3°C) | <50 |
| Pointing Stability Over Temperature(μrad/°C) | <8 |
| Beam height from base plate (mm) | 27.4 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
MGL-FN-550: Collimation benefits from a stable, focusable source. 550 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
MGL-FN-550: 550 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MGL-FN-550: 550 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MGL-FN-550: 550 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect MGL-FN-550 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating Temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · Beam divergence, full angle (mrad): <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MGL-FN-550 with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MGL-FN-550 (current) | FL-550-SLM | MLL-U-550 |
|---|---|---|---|
| Wavelength | 550 nm | 550 nm | 550 nm |
| Optical power / pulse energy | 1~500 mW | 1~500 mW | 1~100 mW |
| Operating mode / pulse width | CW | CW | CW |
| Beam quality | TEM00 | <1.1 | TEM00 |
Compare the MGL-FN-550 with nearby fiber lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
PhotonicsSingle-mode fiber does not preserve polarization. Pin the state, erase it with a scrambler, or maintain it in PM fiber — which one your measurement needs, and the response time and extinction ratio that decide it.
Open guide