ICP-MS
LPS-355-Q Small size: 355 nm emission determines compatible optics, coatings and detectors for ICP-MS. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.
Pulse energy, repetition rate, pulse width
LPS-355-Q Small size is a 355 nm Pulsed laser. Used for icp-ms, lcd repair, scientific research, laser processing. Key specifications: pulse energy 1-10 mJ, repetition rate <10 Hz, operating mode Actively Q-switched. View specifications, datasheet and enquiry options from Precisometer.
Specifications
20 specification rows
| Pulse energy | 1-10 mJ |
|---|---|
| Repetition rate | <10 Hz |
| Operating mode | Actively Q-switched |
| Pulse duration (ns) | <10 |
| Jitter (ns, sdev) | <1ns (Int.) |
| energy | lamp / pumped / solid / state |
| of high single pulse energy ,short pulse | Beam divergence, full angle (mrad) / <3 |
| Beam diameter (mm) | ~9 |
| Warm-up time (minutes) | <15 |
| Cooled method | Water cooled |
| Operating temperature (℃) | 15-35 |
| Power supply (110/220VAC) | PSU-LPS-Q(3U) |
| Expected lifetime (pulses) | 107-108 |
| Wavelength (nm) | 355±1 |
| Single pulse energy (mJ) | 80-200 |
| Rep. rate | 1-10Hz (adjustable), single shot (optional) |
| Energy stability (std dev/mean) | <5%, <3% |
| Beam divergence, full angle (mrad) | <3 |
| Beam height from base plate (mm) | 69 |
| Available options | Accessories |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
LPS-355-Q Small size: 355 nm emission determines compatible optics, coatings and detectors for ICP-MS. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.
LPS-355-Q Small size: 355 nm emission determines compatible optics, coatings and detectors for LCD repair. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.
LPS-355-Q Small size: 355 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.
LPS-355-Q Small size: Laser processing depends on how optical energy is delivered to the target; 355 nm emission governs absorption, while the listed temporal parameter (1-10 mJ) governs peak intensity and heat deposition.
System integration
Use these checks to connect LPS-355-Q Small size to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Water cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam diameter (mm): ~9 · Beam divergence, full angle (mrad): <3. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare LPS-355-Q Small size with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | LPS-355-Q Small size (current) | MPL-FN-355 | MPL-F-355 |
|---|---|---|---|
| Wavelength | 355 nm | 355 nm | 355 nm |
| Optical power / pulse energy | 1-10 mJ | 1~30 mW | 1~100 mW |
| Operating mode / pulse width | <10 Hz | 10 Hz-3 kHz | 1-7 kHz |
| Beam quality | <3 | TEM00 | TEM00 |
Compare the LPS-355-Q Small size with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide