Back to Home

Pulse energy, repetition rate, pulse width

HPL-MIR-39003900 nm infrared Q-switched pulsed laser

3900 nm

HPL-MIR-3900 is a 3900 nm Pulsed laser. Used for laser surgery, remote sensing, atmospheric communication, systems for environmental monitoring. Q-switched Mid-Infrared Laser. Key specifications: operating mode Q-switched, output / average power 1~1000 mW, power stability (rms, over 4 hours) <3%, <5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

HPL-MIR-3900

14 specification rows

Operating modeQ-switched
Output / average power1~1000 mW
Beam / notesQ-switched Mid-Infrared Laser
Power stability (rms, over 4 hours)<3%, <5%
Rep.rate (kHz)10
Pulse duration (ns)<50
Beam divergence, full angle (mrad)<5
Beam diameter at the aperture (1/e2,mm)<6
Operating temperature (℃)15~35
Power supply (90-264VAC)PSU-MIR (3U)
Expected lifetime (hours)10000
Warranty period1 year
Wavelength (nm)3900
Beam height from base plate (mm)61

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Laser surgery

HPL-MIR-3900: 3900 nm emission determines compatible optics, coatings and detectors for Laser surgery. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

Remote sensing

HPL-MIR-3900: 3900 nm emission determines compatible optics, coatings and detectors for Remote sensing. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

Atmospheric communication

HPL-MIR-3900: 3900 nm emission must sit inside the fiber-component passband used for Atmospheric communication; connector polish, fiber mode, linewidth and back-reflection tolerance should be specified as one optical interface.

Systems for environmental monitoring

HPL-MIR-3900: 3900 nm emission determines compatible optics, coatings and detectors for Systems for environmental monitoring. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect HPL-MIR-3900 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 15~35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <5 · Beam diameter at the aperture (1/e2,mm): <6
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for HPL-MIR-3900

What cooling does the HPL-MIR-3900 require?

Operating temperature (℃): 15~35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the HPL-MIR-3900 deliver?

Beam divergence, full angle (mrad): <5 · Beam diameter at the aperture (1/e2,mm): <6. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare HPL-MIR-3900 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterHPL-MIR-3900 (current)EO-XS-2600-4410MIL-PS-3967
Wavelength3900 nm3900 nm3967 nm
Optical power / pulse energy1~1000 mW1~1000 mW1~600 mW
Operating mode / pulse widthQ-switchedQ-switchedPulsed
Beam quality<5<5Confirm for this model