Back to Home

Pulse energy, repetition rate, pulse width

HPL-MIR-40004000 nm infrared Q-switched pulsed laser

4000 nm

HPL-MIR-4000 is a 4000 nm Pulsed laser. Used for laser surgery, remote sensing, atmospheric communication, systems for environmental monitoring. Q-switched Mid-Infrared Laser. Key specifications: operating mode Q-switched, output / average power 1~2 W, power stability (rms, over 4 hours) <3%, <5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

HPL-MIR-4000

14 specification rows

Operating modeQ-switched
Output / average power1~2 W
Beam / notesQ-switched Mid-Infrared Laser
Power stability (rms, over 4 hours)<3%, <5%
Power supply (90-264VAC)PSU-MIR (3U)
Wavelength (nm)4000
Rep.rate (kHz)10
Pulse duration (ns)<50
Beam divergence, full angle (mrad)<5
Beam diameter at the aperture (1/e2,mm)<6
Beam height from base plate (mm)61
Operating temperature (℃)15~35
Expected lifetime (hours)10000
Warranty period1 year

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Laser surgery

HPL-MIR-4000: 4000 nm emission determines compatible optics, coatings and detectors for Laser surgery. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

Remote sensing

HPL-MIR-4000: 4000 nm emission determines compatible optics, coatings and detectors for Remote sensing. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

Atmospheric communication

HPL-MIR-4000: 4000 nm emission must sit inside the fiber-component passband used for Atmospheric communication; connector polish, fiber mode, linewidth and back-reflection tolerance should be specified as one optical interface.

Systems for environmental monitoring

HPL-MIR-4000: 4000 nm emission determines compatible optics, coatings and detectors for Systems for environmental monitoring. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect HPL-MIR-4000 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 15~35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <5 · Beam diameter at the aperture (1/e2,mm): <6
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for HPL-MIR-4000

What cooling does the HPL-MIR-4000 require?

Operating temperature (℃): 15~35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the HPL-MIR-4000 deliver?

Beam divergence, full angle (mrad): <5 · Beam diameter at the aperture (1/e2,mm): <6. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare HPL-MIR-4000 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterHPL-MIR-4000 (current)EO-XS-4000EO-XS-2600-4410
Wavelength4000 nm4000 nm4000 nm
Optical power / pulse energy1~2 W1~400 mW1~1000 mW
Operating mode / pulse widthQ-switchedQ-switchedQ-switched
Beam quality<5<5<5