Back to Home

Pulse energy, repetition rate, pulse width

EO-XS-2600-44104400 nm infrared Q-switched pulsed laser

4400 nm

EO-XS-2600-4410 is a 4400 nm Pulsed laser. Used for medical treatment, scientific research. Q-switched Mid-Infrared Laser. Key specifications: operating mode Q-switched, output / average power 1~1000 mW, power stability (rms, 4 hours±3℃) <5%, <3%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

EO-XS-2600-4410

12 specification rows

Wavelength4400 nm
Operating modeQ-switched
Output / average power1~1000 mW
Beam / notesQ-switched Mid-Infrared Laser
Power stability (rms, 4 hours±3℃)<5%, <3%
Rep. rate30-50kHz
Single pulse energy (µJ)1-33.3 / 1-26.7 / 1-13.3 / 1-6.7
Beam divergence, full angle (mrad)<5
Warm-up time (minutes)<10
Cooled methodAir cooled
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-AOM (3U)
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical treatment

EO-XS-2600-4410: 4400 nm emission determines compatible optics, coatings and detectors for Medical treatment. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

Scientific research

EO-XS-2600-4410: 4400 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect EO-XS-2600-4410 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for EO-XS-2600-4410

What cooling does the EO-XS-2600-4410 require?

Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the EO-XS-2600-4410 deliver?

Beam divergence, full angle (mrad): <5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare EO-XS-2600-4410 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterEO-XS-2600-4410 (current)HPL-MIR-4400HPL-MIR-4500
Wavelength4400 nm4400 nm4500 nm
Optical power / pulse energy1~1000 mW1~2 W1~2 W
Operating mode / pulse widthQ-switchedQ-switchedQ-switched
Beam quality<5<5Confirm for this model