Optical instrumentation
EO-LS-515: 515 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<1) helps predict how the source will focus and propagate through the instrument.
Pulse energy, repetition rate, pulse width
EO-LS-515 is a 515 nm Pulsed laser. Q-switched Green Laser. Key specifications: operating mode Q-switched, output / average power 0.4 W, pulse energy 0.4 mJ. View specifications, datasheet and enquiry options from Precisometer.
Specifications
19 specification rows
| Operating mode | Q-switched |
|---|---|
| Output / average power | 0.4 W |
| Pulse energy | 0.4 mJ |
| Beam / notes | Q-switched Green Laser |
| Rep. rate (kHz) | 1 |
| Pulse duration (ns) | <20 |
| Ave power stability (rms, 4 hours±3℃) | <5%, <3% |
| Warm-up time (minutes) | <10 |
| Cooled method | Air cooled |
| Operating temperature (℃) | 10-35 |
| Power supply (100-240VAC) | PSU-AOM(3U) |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 515±1 |
| Single pulse energy (uJ) | 1-400 |
| Peak power (kW) | 0.05-20 |
| Beam divergence, full angle (mrad) | <1 |
| Beam diameter at the aperture (1/e2,mm) | ~2 |
| M² | <1.3 |
| Beam height from base plate (mm) | 109 |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
EO-LS-515: 515 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<1) helps predict how the source will focus and propagate through the instrument.
EO-LS-515: Laboratory measurement benefits from a stable, focusable source. 515 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1) informs waist size and propagation.
System integration
Use these checks to connect EO-LS-515 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam divergence, full angle (mrad): <1 · Beam diameter at the aperture (1/e2,mm): ~2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare EO-LS-515 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | EO-LS-515 (current) | FS-H- 515A | FS-H- 515B |
|---|---|---|---|
| Wavelength | 515 nm | 515 nm | 515 nm |
| Optical power / pulse energy | 0.4 W | 1-100 mW | 100-1000 mW |
| Operating mode / pulse width | Q-switched | Pulsed | Pulsed |
| Beam quality | <1 | TEM00 | TEM00 |
Compare the EO-LS-515 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide