Lidar
DPS-1535-P: Lidar depends on how optical energy is delivered to the target; 1535 nm emission governs absorption, while the listed temporal parameter (400 / 500 / 40) governs peak intensity and heat deposition.
Pulse energy, repetition rate, pulse width
DPS-1535-P is a 1535 nm Pulsed laser. Used for lidar, laser ranging, optical communication, target indication. Q-switched Infrared Laser. Key specifications: operating mode Q-switched, output / average power 4 mW, single pulse energy (uj) 400 / 500 / 40. View specifications, datasheet and enquiry options from Precisometer.
Specifications
18 specification rows
| Operating mode | Q-switched |
|---|---|
| Output / average power | 4 mW |
| Beam / notes | Q-switched Infrared Laser |
| Single pulse energy (uJ) | 400 / 500 / 40 |
| High energy diode pumped all solid state | Pulse duration (ns) / 3-6 |
| Rep. rate | 1-10Hz (optional) / 1000Hz |
| M2 | ≤1.3 / ≤1.5 |
| Beam diameter (mm) | ~1 |
| Beam divergence, full angle (mrad) | ≤15 |
| Warm-up time (seconds) | <10 |
| Cooled method | Conduction |
| Operating temperature (℃) | -20~60 |
| Power supply (5VDC) | PSU-DPS-P |
| Expected lifetime (pulses) | >107 |
| Wavelength (nm) | 1535±5 |
| Pulse duration (ns) | 3-6 |
| Energy stability (rms) | ≤5% |
| Beam height from base plate (mm) | 3.85 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
DPS-1535-P: Lidar depends on how optical energy is delivered to the target; 1535 nm emission governs absorption, while the listed temporal parameter (400 / 500 / 40) governs peak intensity and heat deposition.
DPS-1535-P: 1535 nm emission determines compatible optics, coatings and detectors for Laser ranging. The catalogued beam parameter (≤15) helps predict how the source will focus and propagate through the instrument.
DPS-1535-P: 1535 nm emission must sit inside the fiber-component passband used for Optical communication; connector polish, fiber mode, linewidth and back-reflection tolerance should be specified as one optical interface.
DPS-1535-P: 1535 nm emission determines compatible optics, coatings and detectors for Target indication. The catalogued beam parameter (≤15) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect DPS-1535-P to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Conduction · Operating temperature (℃): -20~60. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
M2: ≤1.3 / ≤1.5 · Beam diameter (mm): ~1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare DPS-1535-P with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | DPS-1535-P (current) | MPL-E-1535 | MPL-T-1535 |
|---|---|---|---|
| Wavelength | 1535 nm | 1535 nm | 1535 nm |
| Optical power / pulse energy | 4 mW | 0.1~1 mW | 0.1~1 mW |
| Operating mode / pulse width | Q-switched | Q-switched | Q-switched |
| Beam quality | ≤15 | 3.85 | TEM00 |
Compare the DPS-1535-P with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide