Back to Home

Pulse energy, repetition rate, pulse width

FS-H- 1560A1560 nm infrared pulsed laser

1560 nm

FS-H- 1560A is a 1560 nm Pulsed laser. Used for optical microscope, photon imaging, physics experiment. Key specifications: operating mode Pulsed, output / average power 1-200 mW, repetition rate 80±2 MHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FS-H- 1560A

21 specification rows

Operating modePulsed
Output / average power1-200 mW
Repetition rate80±2 MHz
Single pulse energy (nJ)1-2.5
Pulse duration (fs)<50
Warm-up time (minutes)<10
Transverse modeTEM00
M2 factor<1.2
Polarization ratio>100:1 after PM fiber
Cooled methodAir cooled
Operating temperature (℃)10-35
Power supply (100-240VAC)12V/6.67A
Expected lifetime (hours)>10000
Pulse width<50 @80MHz
Wavelength (nm)1560±30
Average power (mW)1-200
Rep. rate (MHz)80±2
Peak power (kW)1-50
Ave power stability (rms, 4 hours±3℃)<2%, <1%
<1.2
Output formPM1550fiber, FC/ APC connector

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Optical microscope

FS-H- 1560A: 1560 nm emission can be matched to the absorption or excitation band used in Optical microscope. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Photon imaging

FS-H- 1560A: 1560 nm emission can be matched to the absorption or excitation band used in Photon imaging. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Physics experiment

FS-H- 1560A: Physics experiment benefits from a stable, focusable source. 1560 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect FS-H- 1560A to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2 factor: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for FS-H- 1560A

What cooling does the FS-H- 1560A require?

Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the FS-H- 1560A deliver?

Transverse mode: TEM00 · M2 factor: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FS-H- 1560A with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFS-H- 1560A (current)FS-H-1560AFC-OEM-1560
Wavelength1560 nm1560 nm1560 nm
Optical power / pulse energy1-200 mW1~200 mW1~15 mW
Operating mode / pulse widthPulsedPulsedConfirm for this model
Beam qualityTEM00TEM00Confirm for this model