Flow cytometry
AO-U-262/1-80uJ: 262 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Pulse energy, repetition rate, pulse width
AO-U-262/1-80uJ is a 262 nm Pulsed laser. Used for flow cytometry, dna sequencing, optical instrument, medical imaging. �� �� �� �� �� �� Actively Q-switched UV Laser AO-U-262/ 1-80uJ/ 1-250mW. Key specifications: operating mode Q-switched, output / average power 1-250 mW. View specifications, datasheet and enquiry options from Precisometer.
Specifications
3 specification rows
| Wavelength | 262 nm |
|---|---|
| Operating mode | Q-switched |
| Output / average power | 1-250 mW |
| Beam / notes | �� �� �� �� �� �� Actively Q-switched UV Laser AO-U-262/ 1-80 uJ/ 1-250 mW |
Series-level technical context
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near pulsed lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Nearby series records state M²: <2, M²: <2.0, M²: <1.2, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for AO-U-262/1-80uJ; confirm them on the order-specific datasheet.
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
AO-U-262/1-80uJ: 262 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
AO-U-262/1-80uJ: 262 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
AO-U-262/1-80uJ: 262 nm emission determines compatible optics, coatings and detectors for Optical instrument. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
AO-U-262/1-80uJ: 262 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare AO-U-262/1-80uJ with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | AO-U-262/1-80uJ (current) | UV-DP-261-LN | UV-FN-261 |
|---|---|---|---|
| Wavelength | 262 nm | 261 nm | 261 nm |
| Optical power / pulse energy | 1-250 mW | 1~800 mW | 1~10 mW |
| Operating mode / pulse width | Q-switched | CW | CW |
| Beam quality | Confirm for this model | Near TEM00 | TEM00 |
Compare the AO-U-262/1-80uJ with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide