UV-DP-261-B is a 261 nm CW laser. Used for flow cytometry, dna sequencing, optical instrument, medical imaging. Features: Water Cooled. Key specifications: output / average power 100~1500 mW, spectral linewidth <0.2 nm, power stability <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
UV-DP-261-B: 261 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
UV-DP-261-B: 261 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Optical instrument
UV-DP-261-B: 261 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.
Medical imaging
UV-DP-261-B: 261 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
System integration
Integration and compatibility
Use these checks to connect UV-DP-261-B to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method (Water Cooled): WCH-580 · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam diameter at the aperture (1/e2, mm): <3.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for UV-DP-261-B
What cooling does the UV-DP-261-B require?+
Cooled method (Water Cooled): WCH-580 · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the UV-DP-261-B deliver?+
Transverse mode: Near TEM00 · Beam diameter at the aperture (1/e2, mm): <3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare UV-DP-261-B with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.