Optical instrumentation
AO-RM-590: 590 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.
Pulse energy, repetition rate, pulse width
AO-RM-590 is a 590 nm Pulsed laser. Q-switched Yellow Laser. Key specifications: operating mode Q-switched, output / average power 1~1000 mW, pulse energy 1~200 uJ. View specifications, datasheet and enquiry options from Precisometer.
Specifications
14 specification rows
| Operating mode | Q-switched |
|---|---|
| Output / average power | 1~1000 mW |
| Pulse energy | 1~200 uJ |
| Beam / notes | Q-switched Yellow Laser |
| Wavelength (nm) | 590±1 |
| Pulse duration (ns) | <25ns |
| Rep. rate (kHz) | 5 |
| Single pulse energy (µJ) | 1-200 |
| Beam diameter at the aperture (1/e2, mm) | <4 |
| Beam divergence, full angle (mrad) | <3 |
| Ave power stability (over 4hours) | <5%, <3% |
| Warm-up time (minutes) | <10 |
| Operating temperature (°C) | 15~30 |
| Expected lifetime (hours) | 10000 |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
AO-RM-590: 590 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.
AO-RM-590: Laboratory measurement benefits from a stable, focusable source. 590 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<3) informs waist size and propagation.
System integration
Use these checks to connect AO-RM-590 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (°C): 15~30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam diameter at the aperture (1/e2, mm): <4 · Beam divergence, full angle (mrad): <3. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare AO-RM-590 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
Compare the AO-RM-590 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide