Back to Home

Pulse energy, repetition rate, pulse width

HPL-589.159-Q589.159 nm yellow Q-switched pulsed laser

589.159 nm

HPL-589.159-Q is a 589.159 nm Pulsed laser. High Power Yellow DPSS Laser; For laser guide star (LGS. Key specifications: output / average power 1~5 W, pulse energy >1 mJ, operating mode Actively Q-switched. View specifications, datasheet and enquiry options from Precisometer.

Specifications

HPL-589.159-Q

19 specification rows

Output / average power1~5 W
Pulse energy>1 mJ
Beam / notesHigh Power Yellow DPSS Laser; For laser guide star (LGS
Operating modeActively Q-switched
Rep. rate5±1kHz
Linewidth (GHz)3
Power stability (rms)<5%, <3%
Warm-up time (minutes)<15
Cooled methodWater cooled
Operating temperature (℃)15-35
Power supply (110/220VAC)PSU-HPL-589.159
Expected lifetime (hours)>10000
Wavelength (nm)589.159±0.001
Pulse duration (ns)100-150@5W(nonadjustable)
Spectrum tuning range (GHz)15
Peak power (kW)8
Beam divergence, full angle (mrad)<3
Beam diameter at the aperture (mm)~18
Beam height from base plate (mm)90

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

HPL-589.159-Q: 589.159 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

HPL-589.159-Q: Laboratory measurement benefits from a stable, focusable source. 589.159 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<3) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect HPL-589.159-Q to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Water cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <3 · Beam diameter at the aperture (mm): ~18
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for HPL-589.159-Q

What cooling does the HPL-589.159-Q require?

Cooled method: Water cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the HPL-589.159-Q deliver?

Beam divergence, full angle (mrad): <3 · Beam diameter at the aperture (mm): ~18. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare HPL-589.159-Q with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterHPL-589.159-Q (current)LGS-589.159-PS589
Wavelength589.159 nm589.159 nm589 nm
Optical power / pulse energy1~5 W1-25 W1-50 W
Operating mode / pulse widthActively Q-switchedMode-lockedQ-switched
Beam quality<3<1.5Confirm for this model