Laser inner carver
AO-Mini-E-355: 355 nm emission determines compatible optics, coatings and detectors for Laser inner carver. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
Pulse energy, repetition rate, pulse width
AO-Mini-E-355 is a 355 nm Pulsed laser. Used for laser inner carver, laser marking, scientific research. Key specifications: output / average power 1~1000 mW, pulse energy 1~150 uJ, repetition rate 1 Hz-100 kHz. View specifications, datasheet and enquiry options from Precisometer.
Specifications
16 specification rows
| Output / average power | 1~1000 mW |
|---|---|
| Pulse energy | 1~150 uJ |
| Repetition rate | 1 Hz-100 kHz |
| Pulse width | ~9 ns @1 Hz-1 kHz |
| Wavelength (nm) | 355±1 |
| Operating mode | Actively Q-switched |
| Power stability (rms, 4 hours ± 3°C) | <2%, <1% |
| Transverse mode | TEM00 |
| M² | <1.2 |
| Polarization ratio | >100:1 Vertical |
| Warm-up time (minutes) | <10 |
| Beam height from base plate (mm) | 81.4mm |
| Cooled method | Air cooled |
| Operating temperature (℃) | 10-35 |
| Operating voltage (VDC) | 24V/14.5A |
| Expected lifetime (hours) | >10000 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
AO-Mini-E-355: 355 nm emission determines compatible optics, coatings and detectors for Laser inner carver. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
AO-Mini-E-355: Laser marking depends on how optical energy is delivered to the target; 355 nm emission governs absorption, while the listed temporal parameter (1~150 uJ) governs peak intensity and heat deposition.
AO-Mini-E-355: 355 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect AO-Mini-E-355 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · M²: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare AO-Mini-E-355 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | AO-Mini-E-355 (current) | MPL-FN-355 | MPL-F-355 |
|---|---|---|---|
| Wavelength | 355 nm | 355 nm | 355 nm |
| Optical power / pulse energy | 1~1000 mW | 1~30 mW | 1~100 mW |
| Operating mode / pulse width | 1 Hz-100 kHz | 10 Hz-3 kHz | 1-7 kHz |
| Beam quality | TEM00 | TEM00 | TEM00 |
Compare the AO-Mini-E-355 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide