Back to Home

Pulse energy, repetition rate, pulse width

AO-K-579579 nm yellow Q-switched pulsed laser

579 nm

AO-K-579 is a 579 nm Pulsed laser. Q-switched Yellow Laser; High beam quality. Key specifications: operating mode Q-switched, output / average power 1~250 mW, pulse energy 1~25 uJ. View specifications, datasheet and enquiry options from Precisometer.

Specifications

AO-K-579

18 specification rows

Operating modeQ-switched
Output / average power1~250 mW
Pulse energy1~25 uJ
Beam / notesQ-switched Yellow Laser; High beam quality
Rep. rate (kHz)10
Pulse duration (ns)<15
Power stability (rms, over 4 hours)<3%,5%
Cooled methodAir Cooled
Power supplyPSU-AOM (3U)
Expected lifetime (hours)10000
Warranty period1 year
Central wavelength (nm)579±2
Single pulse energy (µJ)1~25
Peak power(kW)1.7
Beam diameter at the aperture (1/e2, mm)<3
Beam divergence, full angle (mrad)<2
Beam height from base plate (mm)120
Warm-up time (minutes)<10

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

AO-K-579: 579 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<2) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

AO-K-579: Laboratory measurement benefits from a stable, focusable source. 579 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<2) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect AO-K-579 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air Cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam diameter at the aperture (1/e2, mm): <3 · Beam divergence, full angle (mrad): <2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for AO-K-579

What cooling does the AO-K-579 require?

Cooled method: Air Cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the AO-K-579 deliver?

Beam diameter at the aperture (1/e2, mm): <3 · Beam divergence, full angle (mrad): <2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare AO-K-579 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterAO-K-579 (current)589HPL-589-Q
Wavelength579 nm589 nm589 nm
Optical power / pulse energy1~250 mW1-50 W1-50 W
Operating mode / pulse widthQ-switchedQ-switchedQ-switched
Beam quality<2Confirm for this model<3