Back to Home

Pulse energy, repetition rate, pulse width

355355 nm UV pulsed laser

355 nm

355 is a 355 nm Pulsed laser. Used for optical microscope, photon imaging, physics experiment. Rep. rate (Hz): 0-1000 kHz; Cooled method: Water cooled. Key specifications: pulse energy 30 uJ, repetition rate 0-1000 kHz, pulse width <15 ps. View specifications, datasheet and enquiry options from Precisometer.

Specifications

355

5 specification rows

Wavelength355 nm
Pulse energy30 uJ
Repetition rate0-1000 kHz
Beam / notesRep. rate (Hz): 0-1000 kHz; Cooled method: Water cooled
Pulse width<15 ps
CoolingWater cooled

Application context

Why this design is used

Applications named on a datasheet for this product line, interpreted against this model’s listed wavelength and beam data.

Optical microscope

355: 355 nm emission can be matched to the absorption or excitation band used in Optical microscope. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Photon imaging

355: 355 nm emission can be matched to the absorption or excitation band used in Photon imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Physics experiment

355: Physics experiment benefits from a stable, focusable source. 355 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

System integration

Integration and compatibility

Use these checks to connect 355 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooling: Water cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Technical FAQ

Integration questions for 355

What cooling does the 355 require?

Cooling: Water cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare 355 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameter355 (current)MPL-FN-355MPL-F-355
Wavelength355 nm355 nm355 nm
Optical power / pulse energy30 uJ1~30 mW1~100 mW
Operating mode / pulse width0-1000 kHz10 Hz-3 kHz1-7 kHz
Beam qualityConfirm for this modelTEM00TEM00