Back to Home

Microscopy Camera/Microscope Camera

SCMOS02100KPA

SCMOS02100KPA Microscopy Camera/Microscope Camera with IMX307 (C) sensor, 2.1MP (1920×1080) for professional imaging.

Sensor
IMX307 (C)
Resolution
2.1MP (1920×1080)
Pixel Size
2.9 µm × 2.9 µm
Frame Rate
38 fps @ 1920×1080; 38 fps @ 1024×768
Interface
USB2.0
SCMOS02100KPA

Application context

Why this design is used

Scientific imaging

SCMOS02100KPA: The IMX307 (C) sensor, 2.1MP (1920×1080) resolution, and 2.9 µm × 2.9 µm pixels defines the sensitivity, sampling and field coverage available for Scientific imaging. The 38 fps @ 1920×1080; 38 fps @ 1024×768 frame-rate listing also sets the fastest full-frame acquisition regime.

Instrument integration

SCMOS02100KPA: The IMX307 (C) sensor, 2.1MP (1920×1080) resolution, and 2.9 µm × 2.9 µm pixels defines the sensitivity, sampling and field coverage available for Instrument integration. The 38 fps @ 1920×1080; 38 fps @ 1024×768 frame-rate listing also sets the fastest full-frame acquisition regime.

Specifications

SCMOS02100KPA

22 specification rows

The SCMOS02100KPA is a microscopy camera in the SCMOS series, built around a IMX307 (C) sensor, 2.1MP (1920×1080) resolution, 2.9 µm × 2.9 µm pixels, frame rates up to 38 fps @ 1920×1080; 38 fps @ 1024×768, a USB2.0 interface. It suits microscopy camera/microscope camera where reliable imaging performance and interface compatibility matter.

Key Parameters

ModelSCMOS02100KPA
SensorIMX307 (C)
Effective Pixels / Resolution2.1MP (1920×1080)
Frame Rate (Full Resolution)38 fps @ 1920×1080; 38 fps @ 1024×768
Shutter TypeElectronic Rolling Shutter
Color TypeColor

Imaging Performance

Pixel Size2.9 µm × 2.9 µm
Sensor Size5.73 mm × 4.3 mm
Diagonal1/2.5" (7.16 mm)
Dynamic Range73 dB
Bit DepthAvailable on request
Sensitivity1300 mV

Interface & Mechanical

Data InterfaceUSB2.0
GPIOAvailable on request
Lens Mount23.2 mm eyepiece tube type
DimensionsDia. 27.2 mm × 40 mm
Weight0.15~0.16Kg
Power SupplyUSB powered

Environment & Certification

Operating Temperature / Humidity10 °C ~ +50 °C / 30%~80%RH
Storage Temperature / Humidity20 °C ~ +60 °C / 10%~60%RH
Operating SystemMicrosoft Windows XP/Vista/7/8/10/11(32&64-bit)
CertificationCE/FCC

System integration

Integration and compatibility

Use these checks to connect SCMOS02100KPA to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Lens and microscope interface
Lens Mount: 23.2 mm eyepiece tube type
Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.
Sensor and sampling
Sensor: IMX307 (C) · Resolution: 2.1MP (1920×1080)
Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.
Interface and data rate
Frame Rate: 38 fps @ 1920×1080; 38 fps @ 1024×768 · Interface: USB2.0
Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.
Hardware synchronization
GPIO: Available on request
Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.
Cooling and noise floor
Dynamic Range: 73 dB
Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Technical FAQ

Integration questions for SCMOS02100KPA

What lens mount is required for the SCMOS02100KPA?

Lens Mount: 23.2 mm eyepiece tube type. Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.

What sensor and pixel pitch does the SCMOS02100KPA use?

Sensor: IMX307 (C) · Resolution: 2.1MP (1920×1080). Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.

How does the SCMOS02100KPA connect to the acquisition computer?

Frame Rate: 38 fps @ 1920×1080; 38 fps @ 1024×768 · Interface: USB2.0. Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.

Does the SCMOS02100KPA support hardware triggering?

GPIO: Available on request. Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.

What is the noise performance of the SCMOS02100KPA?

Dynamic Range: 73 dB. Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Need help choosing?

Tell us your sensor, resolution, spectral range, frame-rate, interface, and software requirements and we will confirm the matching configuration and lead time.

Open camera finder

Model selection

Nearby series comparison

Compare SCMOS02100KPA with the closest available models in the SCMOS family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterSCMOS02100KPA (current)SCMOS02000KPBSCMOS02100KPB
SensorIMX307 (C)OV2710 (C)SC2332 (C)
Resolution2.1MP (1920×1080)2.0MP (1920×1080)2.1MP (1920×1080)
Sensor size5.73 mm × 4.3 mm5.76 mm × 3.24 mm5.18 mm × 2.92 mm
Pixel size / frame rate2.9 µm × 2.9 µm3 µm × 3 µm2.7 µm × 2.7 µm

Other cameras on the IMX307 sensor

The IMX307 appears in 8 models across the catalogue, differing in cooling, shutter, interface and colour filter. Compare them side by side before settling on a variant.