Back to Home

Industrial Camera/Analytical Imaging

IUA20400KMA

IUA20400KMA Industrial Camera/Analytical Imaging with Sony IMX541-AAMJ-C sensor, 20.4MP (4496×4496) for professional imaging.

Sensor
Sony IMX541-AAMJ-C
Resolution
20.4MP (4496×4496)
Pixel Size
2.74 µm × 2.74 µm
Frame Rate
17.5 fps @ 4496×4496; 64.4 fps @ 2240×2240; 64.4 fps @ 1120×1120
Interface
USB3.0 (USB3.1 GEN1)
IUA20400KMA

Application context

Why this design is used

Scientific imaging

IUA20400KMA: The Sony IMX541-AAMJ-C sensor, 20.4MP (4496×4496) resolution, and 2.74 µm × 2.74 µm pixels defines the sensitivity, sampling and field coverage available for Scientific imaging. The 17.5 fps @ 4496×4496; 64.4 fps @ 2240×2240; 64.4 fps @ 1120×1120 frame-rate listing also sets the fastest full-frame acquisition regime.

Instrument integration

IUA20400KMA: The Sony IMX541-AAMJ-C sensor, 20.4MP (4496×4496) resolution, and 2.74 µm × 2.74 µm pixels defines the sensitivity, sampling and field coverage available for Instrument integration. The 17.5 fps @ 4496×4496; 64.4 fps @ 2240×2240; 64.4 fps @ 1120×1120 frame-rate listing also sets the fastest full-frame acquisition regime.

Specifications

IUA20400KMA

23 specification rows

The IUA20400KMA is an industrial & analytical camera in the IUA series, built around a Sony IMX541-AAMJ-C sensor, 20.4MP (4496×4496) resolution, 2.74 µm × 2.74 µm pixels, frame rates up to 17.5 fps @ 4496×4496; 64.4 fps @ 2240×2240; 64.4 fps @ 1120×1120, a USB3.0 (USB3.1 GEN1) interface. It suits industrial camera/analytical imaging where reliable imaging performance and interface compatibility matter.

Key Parameters

ModelIUA20400KMA
SensorSony IMX541-AAMJ-C
Effective Pixels / Resolution20.4MP (4496×4496)
Frame Rate (Full Resolution)17.5 fps @ 4496×4496; 64.4 fps @ 2240×2240; 64.4 fps @ 1120×1120
Exposure Time30 µs ~ 15 s
Shutter TypeGlobal shutter
Color TypeMonochrome

Imaging Performance

Pixel Size2.74 µm × 2.74 µm
Sensor Size12.32 mm × 12.32 mm
Diagonal1" (17.42 mm)
Dynamic Range72 dB
Bit Depth8/12-bit
Sensitivity2649 mV

Interface & Mechanical

Data InterfaceUSB3.0 (USB3.1 GEN1)
GPIO1 optically isolated input, 1 optically isolated output, 2 non-isolated input/output
Lens MountC-mount
Dimensions68 mm × 68 mm × 28.1 mm
Weight227g
Power SupplyUSB3.0 interface power / DC 12 V power

Environment & Certification

Operating Temperature / Humidity10 °C ~ +50 °C / 20%~80% non-condensing
Storage Temperature / Humidity30 °C ~ +70 °C / Available on request
Operating SystemWindows 32-bit/Windows RT/Linux/macOS/Android; x86/x64/ARM HF/ARM EL/ARM64
CertificationCE, FCC

System integration

Integration and compatibility

Use these checks to connect IUA20400KMA to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Lens and microscope interface
Lens Mount: C-mount
Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.
Sensor and sampling
Sensor: Sony IMX541-AAMJ-C · Resolution: 20.4MP (4496×4496)
Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.
Interface and data rate
Frame Rate: 17.5 fps @ 4496×4496; 64.4 fps @ 2240×2240; 64.4 fps @ 1120×1120 · Interface: USB3.0 (USB3.1 GEN1)
Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.
Hardware synchronization
GPIO: 1 optically isolated input, 1 optically isolated output, 2 non-isolated input/output
Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.
Cooling and noise floor
Dynamic Range: 72 dB
Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Technical FAQ

Integration questions for IUA20400KMA

What lens mount is required for the IUA20400KMA?

Lens Mount: C-mount. Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.

What sensor and pixel pitch does the IUA20400KMA use?

Sensor: Sony IMX541-AAMJ-C · Resolution: 20.4MP (4496×4496). Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.

How does the IUA20400KMA connect to the acquisition computer?

Frame Rate: 17.5 fps @ 4496×4496; 64.4 fps @ 2240×2240; 64.4 fps @ 1120×1120 · Interface: USB3.0 (USB3.1 GEN1). Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.

Does the IUA20400KMA support hardware triggering?

GPIO: 1 optically isolated input, 1 optically isolated output, 2 non-isolated input/output. Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.

What is the noise performance of the IUA20400KMA?

Dynamic Range: 72 dB. Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Need help choosing?

Tell us your sensor, resolution, spectral range, frame-rate, interface, and software requirements and we will confirm the matching configuration and lead time.

Open camera finder

Model selection

Nearby series comparison

Compare IUA20400KMA with the closest available models in the IUA family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterIUA20400KMA (current)IUA20000KPAIUA20400KPA
SensorSony IMX541-AAMJ-CSony IMX183CQKSony IMX541-AAQJ-C
Resolution20.4MP (4496×4496)20MP (5440×3684)20.4MP (4496×4496)
Sensor size12.32 mm × 12.32 mm13.06 mm × 8.84 mm12.32 mm × 12.32 mm
Pixel size / frame rate2.74 µm × 2.74 µm2.4 µm × 2.4 µm2.74 µm × 2.74 µm

Other cameras on the IMX541 sensor

The IMX541 appears in 6 models across the catalogue, differing in cooling, shutter, interface and colour filter. Compare them side by side before settling on a variant.