Back to Home
MJ120

Opto-Mechanics · MJ Series High Load Lab Jack

MJ120

Lab Jack

View quote list
Datasheet (PDF) ↗CAD Model (RAR) ↗

Catalog context

Where MJ120 fits

MJ120 is listed in the MJ Series High Load Lab Jack family. The local catalog record provides these first selection fields: Travel range(mm): 120; Stage surface height range(mm): 110~230; Stage surface size(mm): 250×150.

Specifications

Travel range(mm)120
Stage surface height range(mm)110~230
Stage surface size(mm)250×150
Drive typeTwo-way fine lead screw,φ12×1.75
Main body material and surfaceBlack anodized aluminum alloy
Load capacity(Kg)30
Weight(Kg)4.5

Application context

Why this design is used

Application guidance is derived from the product family and tied to the model-specific selection fields above.

Set-and-forget alignment

Adjust once during setup and lock, on axes that do not need to move again during the run.

Coarse positioning ahead of fine stages

Establish the optical axis by hand before a piezo or motorised stage takes the fine motion.

Prototyping and teaching rigs

Reconfigure a layout quickly, with no cabling, controllers or electrical noise added to the experiment.

System integration

Integration and compatibility

Use these checks to connect MJ120 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Adjustment
Travel range(mm): 120
Adjuster pitch sets the sensitivity you can actually work at. Confirm whether the stated figure is a total range or a per-revolution increment, and whether the mechanism is locked after adjustment.
Material and finish
Stage surface height range(mm): 110~230 · Stage surface size(mm): 250×150
Aluminium moves about 23 ppm per kelvin and stainless about 16. In a path where thermal drift is already budgeted, the material of the mount belongs in that budget rather than in the appearance of the part.
Dimensions and mass
Load capacity(Kg): 30 · Weight(Kg): 4.5
Use the stated geometry and mass to fix beam height, clearance and the load carried by whatever this part is bolted to. These are the numbers that decide whether adjacent components physically collide.

Technical FAQ

Integration questions for MJ120

What adjustment range does the MJ120 offer?

Travel range(mm): 120. Adjuster pitch sets the sensitivity you can actually work at. Confirm whether the stated figure is a total range or a per-revolution increment, and whether the mechanism is locked after adjustment.

What is the MJ120 made from?

Stage surface height range(mm): 110~230 · Stage surface size(mm): 250×150. Aluminium moves about 23 ppm per kelvin and stainless about 16. In a path where thermal drift is already budgeted, the material of the mount belongs in that budget rather than in the appearance of the part.

What are the dimensions of the MJ120?

Load capacity(Kg): 30 · Weight(Kg): 4.5. Use the stated geometry and mass to fix beam height, clearance and the load carried by whatever this part is bolted to. These are the numbers that decide whether adjacent components physically collide.

Model selection

Nearby series comparison

Compare MJ120 with the closest available models in the MJ Series High Load Lab Jack family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMJ120 (current)MJ240MJ60
Optic acceptedConfirm for this modelConfirm for this modelConfirm for this model
Adjustment12024060
Mounting interfaceConfirm for this modelConfirm for this modelConfirm for this model
Material110~230110~35060~120