Automated scanning and mapping
Step-and-acquire across areas far wider than a single field of view.

Opto-Mechanics · GONX Series Motorized Goniometers
GON motorized single-axis goniometer; 140 mm arc radius; 80 mm platform class; +/-15 deg tilt range; 0.001 deg step size. Options: ST528 stepper-motor bundle.
Datasheet (PDF) ↗Catalog context
GON140-80-ST528 is listed in the GONX Series Motorized Goniometers family. Use the product-family page and any model-specific downloads available here to confirm the required configuration.
Full specifications for this product are available on request. Contact us for the datasheet.
Application context
Application guidance is derived from the product family and tied to the model-specific selection fields above.
Step-and-acquire across areas far wider than a single field of view.
Move parts between fixed stations with closed-loop encoders holding position over long shifts.
Coordinate several axes from software for processing, inspection and test sequences.
Model selection
Compare GON140-80-ST528 with the closest available models in the GONX Series Motorized Goniometers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | GON140-80-ST528 (current) | GON100-80-ST528 | GONX100-80 |
|---|---|---|---|
| Travel / adjustment | Confirm for this model | Confirm for this model | Confirm for this model |
| Resolution / sensitivity | Confirm for this model | Confirm for this model | Confirm for this model |
| Load / optic size | Confirm for this model | Confirm for this model | Confirm for this model |
| Mounting interface | Confirm for this model | Confirm for this model | Confirm for this model |
GONX100-80
GON motorized single-axis goniometer; 100 mm arc radius; 80 mm platform class; +/-15 deg tilt range; 0.001 deg step size.
GONX140-80
GON motorized single-axis goniometer; 140 mm arc radius; 80 mm platform class; +/-15 deg tilt range; 0.001 deg step size.
GON100-80-ST528
GON motorized single-axis goniometer; 100 mm arc radius; 80 mm platform class; +/-15 deg tilt range; 0.001 deg step size. Options: ST528 stepper-motor bundle.
Before you specify
Engineering context for choosing this class of component, with the tradeoffs worked through on real specifications.
Opto-mechanicsVibration, thermal drift and mechanical integration are one problem. Budget the motion at the sample, then specify the table, the isolation, the mounts and the beam height that budget asks for.
Open guide
Optical microscopyDesign the trapping beam, objective, mechanics, imaging, QPD detection, calibration, and safety workflow as one instrument.
Open guide