Automated scanning and mapping
Step-and-acquire across areas far wider than a single field of view.

Opto-Mechanics · TBG Series Motorized Goniometers
TBG two-axis motorized goniometer stack; 80 mm base arc radius; 60 mm platform class; +/-15 deg x +/-15 deg tilt; 0.001 deg step size.
Datasheet (PDF) ↗CAD Model (RAR) ↗Catalog context
TBG80-60 is listed in the TBG Series Motorized Goniometers family. The local catalog record provides these first selection fields: Designed height at center(mm): 80; Stage surface size(mm): 60×60; Angle range(°): ±8.
| Designed height at center(mm) | 80 |
|---|---|
| Stage surface size(mm) | 60×60 |
| Angle range(°) | ±8 |
| Worm gear/worm transmission ratio | 247:1 |
| Guide mechanism | Arc V shaped ball guide |
| Worm gear material | Wear-resistant tin bronze |
| Material and process technology of worm | Steel, high-frequency quench |
| Main body material and surface treatment | Black anodized aluminum alloy |
| Weight(Kg) | 0.9 |
| Shaft coupling (OD - OD1- OD2)(mm) | 42495 |
| Step resolution (°) | ≈0.007 |
| 8-fine-subdivision resolution (°) | ≈0.0009 |
| Max speed(s)* | ≈14 |
| Repositioning accuracy(°) | ≤±0.005 |
| Backlash(µm) | ≤10 |
| Backward rotation clearance(°) | ≤0.01 |
| Thickness(mm) | 35 |
| Swing accuracy at rotation center (mm) | ≤0.01 |
| Stepping motor and its stepping angle (°) | Two-phase 42 stepping motor,1.8 |
| Working current(A) | 1.7 |
| Torque of motor(N-m) | 0.456 |
| Model of motor | SST43D2126-10 |
| Brand and model number of stepping driver (optional) | Moons, SR2 |
| Type of plug for stage | DB9(pin) |
| Type of plug for stage | High flexibility cable (Helukabel, Germany) |
| Length of connection cable(m) | 0.2 |
| Position-limit sensors (built-in) | 2个GP1S092HCPI(Japan SHARP) |
| Origin-point sensors (built-in) | 1个GP1S092HCPI(Japan SHARP) |
| Voltage of power supply for | DC5~24V±10% |
| sensors (V) | <60 (total) |
| Current consumption(mA) | NPN open controller output, DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA) |
| Control output | Output ON when sensor is blocked |
| Horizontal direction(Kg) | 5 |
| Vertical direction(Kg) | 2.5 |
| Inverted direction(Kg) | 3 |
Application context
Application guidance is derived from the product family and tied to the model-specific selection fields above.
Step-and-acquire across areas far wider than a single field of view.
Move parts between fixed stations with closed-loop encoders holding position over long shifts.
Coordinate several axes from software for processing, inspection and test sequences.
System integration
Use these checks to connect TBG80-60 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Step resolution (°): ≈0.007 · 8-fine-subdivision resolution (°): ≈0.0009. Separate travel from resolution and both from repeatability. Repeatability is what an automated sequence actually depends on, and it is the figure most often absent from a headline specification.
Stepping motor and its stepping angle (°): Two-phase 42 stepping motor,1.8 · Torque of motor(N-m): 0.456. Pair open-loop mechanics with the specified high-voltage or inertial driver, and closed-loop variants with the controller their capacitive, strain-gauge or encoder feedback requires. Matching connectors do not guarantee electrical compatibility.
Model selection
Compare TBG80-60 with the closest available models in the TBG Series Motorized Goniometers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | TBG80-60 (current) | TBG45-60-ST542 | TBG80-60-ST542 |
|---|---|---|---|
| Travel / adjustment | Confirm for this model | Confirm for this model | Confirm for this model |
| Resolution / sensitivity | ≈0.007 | Confirm for this model | Confirm for this model |
| Load / optic size | Confirm for this model | Confirm for this model | Confirm for this model |
| Mounting interface | Confirm for this model | Confirm for this model | Confirm for this model |
TBG45-60
TBG two-axis motorized goniometer stack; 45 mm base arc radius; 60 mm platform class; +/-15 deg x +/-15 deg tilt; 0.001 deg step size.
TBG100-80
TBG two-axis motorized goniometer stack; 100 mm base arc radius; 80 mm platform class; +/-15 deg x +/-15 deg tilt; 0.001 deg step size.
TBG140-80
TBG two-axis motorized goniometer stack; 140 mm base arc radius; 80 mm platform class; +/-15 deg x +/-15 deg tilt; 0.001 deg step size.
TBG45-60-ST542
TBG two-axis motorized goniometer stack; 45 mm base arc radius; 60 mm platform class; +/-15 deg x +/-15 deg tilt; 0.001 deg step size. Options: ST542 stepper-motor bundle.
Before you specify
Engineering context for choosing this class of component, with the tradeoffs worked through on real specifications.
Opto-mechanicsVibration, thermal drift and mechanical integration are one problem. Budget the motion at the sample, then specify the table, the isolation, the mounts and the beam height that budget asks for.
Open guide
Optical microscopyDesign the trapping beam, objective, mechanics, imaging, QPD detection, calibration, and safety workflow as one instrument.
Open guide