Back to Home

Fiber Optical Sensor

Multichannel Fiber Optical Temperature Sensor Readout Module

The MFOR Fiber Optic Multichannel Temperature Readouts are compatible with all fiber optic sensor probes, delivering industry-leading accuracy, repeatability, and reliability for temperature monitoring applications. Each Readout can be configured with up to twelve measurement channels, providing significant cost reduction and space savings per measurement point. The MFOR is specifically designed for OEM system integration, with customizable configurations available to meet your specific needs.

Multichannel Fiber Optical Temperature Sensor Readout Module

Configuration options

Build & quote

Configure the options below and add your exact build to the enquiry — we confirm the part number and availability.

Part number: MFOR-011111111

Channel: 1 · Type: Standard · Power Supply: Non · Interface: USB

System integration

Integration and compatibility

Use these checks to connect Multichannel Fiber Optical Temperature Sensor Readout Module to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Optical interface and fiber
Interface: USB, RS232/Modbus® RTU, Ethernet/EtherCat
Specify connector polish and fiber architecture together. FC/PC, FC/APC and SMA interfaces, and single-mode, multimode and polarization-maintaining fibers, impose different return-loss, mode-field and alignment requirements.
Control interface
Power Supply: Non, Yes
Match supply voltage, analog or digital command range, connector pinout and default optical state to the instrument interlock. Confirm the unpowered state explicitly — it decides what happens to the link on a power failure.

Technical FAQ

Integration questions for Multichannel Fiber Optical Temperature Sensor Readout Module

Which fiber and connector does the Multichannel Fiber Optical Temperature Sensor Readout Module use?

Interface: USB, RS232/Modbus® RTU, Ethernet/EtherCat. Specify connector polish and fiber architecture together. FC/PC, FC/APC and SMA interfaces, and single-mode, multimode and polarization-maintaining fibers, impose different return-loss, mode-field and alignment requirements.

Does the Multichannel Fiber Optical Temperature Sensor Readout Module require a controller?

Power Supply: Non, Yes. Match supply voltage, analog or digital command range, connector pinout and default optical state to the instrument interlock. Confirm the unpowered state explicitly — it decides what happens to the link on a power failure.

Need this configured?

Share your wavelength, fiber type, connector, power handling and control requirements and we will qualify the matching configuration and part number.

Model selection

Nearby series comparison

Compare Multichannel Fiber Optical Temperature Sensor Readout Module with the closest available models in the Fiber Optical Sensor family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMultichannel Fiber Optical Temperature Sensor Readout Module (current)Fiber Optical Electric-Field Readout SystemUltra-High Voltage Sensor
Wavelength rangeConfirm for this modelConfirm for this modelConfirm for this model
Optical performanceConfirm for this modelConfirm for this modelConfirm for this model
Fiber typeConfirm for this modelMMF 50/125, SMF 9/125Confirm for this model
Connector / controlUSB, RS232/Modbus® RTU, Ethernet/EtherCatFC/APCConfirm for this model