Manual Stages
NFP-1462SR Manual Linear Stage
- Travel range: 25 mm
- Sensitivity: ≤1 µm
- Stage surface size: 65×65 mm
- Thickness: 23±0.1 mm
Specifications
| Travel range(mm) | 25 |
|---|---|
| Stage surface size(mm) | 65×65 |
| Thickness(mm) | 23±0.1 |
| Guide mechanism | Precise crossed-roller guide |
| Drive type | Micrometer |
| Drive location | Right |
| Main body material and surface treatment | Stainless steel, sandblasting |
| Sensitivity(µm) | ≤1 |
| Minimum reading of mi-crometer(mm) | 0.01 |
| Straightness(um) | ≤3 |
| Load capacity(Kg) | 7 |
| Weight(Kg) | 0.85 |
| Axes of Travel | X |
Construction details
- Guidance assembly: Precise crossed-roller guide.
- Drive assembly: Micrometer.
Downloads
Product comparison
Compare with Thorlabs LNR25M/M
NFP-1462SR and Thorlabs LNR25M/M offer options for manual linear positioning. Compare the listed dimensions and interfaces for your setup.
Reference configuration: manual linear positioning.
| Feature | Available from PrecisometerNFP-1462SR | Comparison referenceThorlabs LNR25M/M |
|---|---|---|
| Translation axes | One linear axis | One linear axis |
| Travel range | 25 mm | 25 mm |
| Guide mechanism | Precise crossed-roller guide | Crossed-roller bearings |
| Drive type | Micrometer | Metric micrometer; 0.5 mm/rev; 10 µm graduations |
| Moving table size | 65×65 mm | 59.4 × 60.0 mm |
| Drive location | Right | End-mounted actuator; side-mount adaptation depends on the Thorlabs accessory |
| Body material / finish | Stainless steel, sandblasting | Steel construction; stainless grade is not established as SUS304 |
| Mounting interfaces | Compare the model drawing; matching hole pattern is not established | Seven M6 top taps; M6 mounting counterbores |
Similar application. Check the interfaces for your setup.
Same published 25 mm travel and crossed-roller positioning mechanism; table dimensions, load ratings and mounting must be checked for the intended setup. Precisometer specifies stainless steel; the reference material is not established as the same stainless grade. This is a comparison of published designs. Direct mechanical interchangeability and equal sensitivity are not established. This comparison covers the listed features and does not establish interchangeability or identical performance.
Comparison references: NFP-1462SR catalogue specifications and Thorlabs LNR25M/M published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.