Back to Home
Desktop Raman Microscope

Finder InsightPro

Small desktop Raman microscope with scientific-research performance

Laser, spectrometer and cooled detector in one 8 kg head unit on a compact upright microscope. Nine configurations at 532, 785 or 1064 nm, from teaching labs to forensic benches.

532 / 785 / 1064 nm< 5 cm⁻¹ resolutionTE-cooled CCD or InGaAs8 kg96-well plate option
Finder Insight Pro desktop Raman microscope

Instrument

Finder Insight Pro Desktop Raman Microscope

Spectrometer, laser and detector sit in the head unit above a compact upright microscope; the optical path is coupled in free space to keep collection efficiency high.

System Highlights

Everything in the Head Unit

No fibre run to a separate spectrograph and no external laser: the Finder Insight Pro keeps the whole optical train in one enclosure and couples it in free space to the microscope.

Research Performance, 8 kg

A 280 × 450 × 200 mm head unit that weighs 8 kg without the microscope, with a direct free-space optical path to maximise light collection.

532, 785 or 1064 nm

Nine configurations: 532 nm at ≥ 100 mW, 785 nm and 1064 nm at ≥ 350 mW, all continuously adjustable from 0 to 100 %.

Built-In Sample Camera

An integrated monitoring path lets you pick the measurement spot visually; it moves in and out of the beam automatically.

Vertical and Horizontal Paths

The vertical path takes almost any sample shape; an optional horizontal accessory measures liquids through glass vials and tubes.

96-Well Plate Automation

An optional 96-well plate stage runs a whole plate unattended for screening and repeat measurements.

INScan-Lite Software

Single, continuous and interval acquisition; fitting, smoothing, peak finding and peak-area calculation; optional spectral database for identifying unknowns.

Configurations

Nine Models, Three Excitation Lines

Within each wavelength the choice is between spectral range and resolution, and between −10 °C and −60 °C detector cooling. Not sure which line suits your samples? See the excitation wavelength guide.

532 nm

Laser power ≥ 100 mW, 0–100 % continuously adjustable · linewidth < 0.05 nm

FI532E10-Pro-M2

Spectral range
150–4400 cm⁻¹
Resolution
< 10 cm⁻¹
Detector
TE-cooled back-illuminated CCD
Effective pixels
2048 × 122
Pixel size
12 × 12 µm
Cooling (typ.)
−10 °C
Integration time
10 ms – 30 s

FI532E10H-Pro-M2

Spectral range
150–2800 cm⁻¹
Resolution
< 8 cm⁻¹
Detector
TE-cooled back-illuminated CCD
Effective pixels
2048 × 122
Pixel size
12 × 12 µm
Cooling (typ.)
−10 °C
Integration time
10 ms – 30 s

FI532E60-Pro-V2

Spectral range
150–5000 cm⁻¹
Resolution
< 10 cm⁻¹
Detector
TE-cooled back-illuminated CCD
Effective pixels
2000 × 256
Pixel size
15 × 15 µm
Cooling (typ.)
−60 °C
Integration time
10 ms – 60 s

FI532E60H-Pro-V2

Spectral range
150–3200 cm⁻¹
Resolution
< 8 cm⁻¹
Detector
TE-cooled back-illuminated CCD
Effective pixels
2000 × 256
Pixel size
15 × 15 µm
Cooling (typ.)
−60 °C
Integration time
10 ms – 60 s

785 nm

Laser power ≥ 350 mW, 0–100 % continuously adjustable · linewidth < 0.1 nm

FI785E10-Pro-M2

Spectral range
150–2000 cm⁻¹
Resolution
< 5 cm⁻¹
Detector
TE-cooled back-illuminated CCD
Effective pixels
2048 × 122
Pixel size
12 × 12 µm
Cooling (typ.)
−10 °C
Integration time
10 ms – 30 s

FI785E10W-Pro-M2

Spectral range
150–3200 cm⁻¹
Resolution
< 10 cm⁻¹
Detector
TE-cooled back-illuminated CCD
Effective pixels
2048 × 122
Pixel size
12 × 12 µm
Cooling (typ.)
−10 °C
Integration time
10 ms – 30 s

FI785E60-Pro-V2

Spectral range
150–2200 cm⁻¹
Resolution
< 6 cm⁻¹
Detector
TE-cooled back-illuminated CCD
Effective pixels
2048 × 122
Pixel size
12 × 12 µm
Cooling (typ.)
−10 °C
Integration time
10 ms – 30 s

FI785T-Pro

Spectral range
150–2000 cm⁻¹
Resolution
< 5 cm⁻¹
Detector
NIR-enhanced back-illuminated CCD
Effective pixels
2048 × 64
Pixel size
12 × 12 µm
Cooling (typ.)
−10 °C
Integration time
10 ms – 30 s

1064 nm

Laser power ≥ 350 mW, 0–100 % continuously adjustable · linewidth < 0.1 nm

FI1064E20-Pro

Spectral range
200–2500 cm⁻¹
Resolution
< 14 cm⁻¹
Detector
TE-cooled InGaAs line array
Effective pixels
512 × 1
Pixel size
25 × 500 µm
Cooling (typ.)
−20 °C
Integration time
10 ms – 60 s

Technical Specifications

Common to All Configurations

Excitation
532 nm (≥ 100 mW) · 785 nm (≥ 350 mW) · 1064 nm (≥ 350 mW); one per instrument, 0–100 % adjustable
Laser linewidth
< 0.05 nm (532 nm) · < 0.1 nm (785 / 1064 nm)
Spectral range
150–5000 cm⁻¹ at most, by model (see configurations)
Spectral resolution
< 5 cm⁻¹ to < 14 cm⁻¹, by model (see configurations)
A/D conversion
16-bit
Interface
USB 2.0
Objective
Standard single lens plus 50× microscope objective
Sample monitoring
Built-in camera path, automatically moved in and out of the beam
Software
INScan-Lite; optional spectral database
Options
Horizontal light path for vials and tubes; 96-well plate stage
Power
100–240 V AC, 50–60 Hz adaptor; 12–24 V DC at 2 A to the instrument
Dimensions
280 × 450 × 200 mm (excluding microscope)
Weight
8 kg (excluding microscope)

Final specifications depend on the selected model and accessories.

Applications

Where the Finder Insight Pro Is Used

  • Biomedicine
  • Polymer chemistry
  • Environmental science
  • Materials science
  • Geological science
  • Cultural-relic identification and restoration
  • Criminal investigation and drug identification

Choosing a Raman System

Need Higher Resolution or Mapping?

New to the technique? Start with the confocal Raman knowledge base.

Interested in the Finder Insight Pro?

Tell us your samples and throughput; we will recommend the excitation line, detector and accessories, and arrange a demonstration.