Finder InsightPro
Small desktop Raman microscope with scientific-research performance
Laser, spectrometer and cooled detector in one 8 kg head unit on a compact upright microscope. Nine configurations at 532, 785 or 1064 nm, from teaching labs to forensic benches.

Instrument
Finder Insight Pro Desktop Raman Microscope
Spectrometer, laser and detector sit in the head unit above a compact upright microscope; the optical path is coupled in free space to keep collection efficiency high.
System Highlights
Everything in the Head Unit
No fibre run to a separate spectrograph and no external laser: the Finder Insight Pro keeps the whole optical train in one enclosure and couples it in free space to the microscope.
Research Performance, 8 kg
A 280 × 450 × 200 mm head unit that weighs 8 kg without the microscope, with a direct free-space optical path to maximise light collection.
532, 785 or 1064 nm
Nine configurations: 532 nm at ≥ 100 mW, 785 nm and 1064 nm at ≥ 350 mW, all continuously adjustable from 0 to 100 %.
Built-In Sample Camera
An integrated monitoring path lets you pick the measurement spot visually; it moves in and out of the beam automatically.
Vertical and Horizontal Paths
The vertical path takes almost any sample shape; an optional horizontal accessory measures liquids through glass vials and tubes.
96-Well Plate Automation
An optional 96-well plate stage runs a whole plate unattended for screening and repeat measurements.
INScan-Lite Software
Single, continuous and interval acquisition; fitting, smoothing, peak finding and peak-area calculation; optional spectral database for identifying unknowns.
Configurations
Nine Models, Three Excitation Lines
Within each wavelength the choice is between spectral range and resolution, and between −10 °C and −60 °C detector cooling. Not sure which line suits your samples? See the excitation wavelength guide.
532 nm
Laser power ≥ 100 mW, 0–100 % continuously adjustable · linewidth < 0.05 nm
FI532E10-Pro-M2
- Spectral range
- 150–4400 cm⁻¹
- Resolution
- < 10 cm⁻¹
- Detector
- TE-cooled back-illuminated CCD
- Effective pixels
- 2048 × 122
- Pixel size
- 12 × 12 µm
- Cooling (typ.)
- −10 °C
- Integration time
- 10 ms – 30 s
FI532E10H-Pro-M2
- Spectral range
- 150–2800 cm⁻¹
- Resolution
- < 8 cm⁻¹
- Detector
- TE-cooled back-illuminated CCD
- Effective pixels
- 2048 × 122
- Pixel size
- 12 × 12 µm
- Cooling (typ.)
- −10 °C
- Integration time
- 10 ms – 30 s
FI532E60-Pro-V2
- Spectral range
- 150–5000 cm⁻¹
- Resolution
- < 10 cm⁻¹
- Detector
- TE-cooled back-illuminated CCD
- Effective pixels
- 2000 × 256
- Pixel size
- 15 × 15 µm
- Cooling (typ.)
- −60 °C
- Integration time
- 10 ms – 60 s
FI532E60H-Pro-V2
- Spectral range
- 150–3200 cm⁻¹
- Resolution
- < 8 cm⁻¹
- Detector
- TE-cooled back-illuminated CCD
- Effective pixels
- 2000 × 256
- Pixel size
- 15 × 15 µm
- Cooling (typ.)
- −60 °C
- Integration time
- 10 ms – 60 s
| Model | Spectral range | Resolution | Detector | Effective pixels | Pixel size | Cooling (typ.) | Integration time |
|---|---|---|---|---|---|---|---|
| FI532E10-Pro-M2 | 150–4400 cm⁻¹ | < 10 cm⁻¹ | TE-cooled back-illuminated CCD | 2048 × 122 | 12 × 12 µm | −10 °C | 10 ms – 30 s |
| FI532E10H-Pro-M2 | 150–2800 cm⁻¹ | < 8 cm⁻¹ | TE-cooled back-illuminated CCD | 2048 × 122 | 12 × 12 µm | −10 °C | 10 ms – 30 s |
| FI532E60-Pro-V2 | 150–5000 cm⁻¹ | < 10 cm⁻¹ | TE-cooled back-illuminated CCD | 2000 × 256 | 15 × 15 µm | −60 °C | 10 ms – 60 s |
| FI532E60H-Pro-V2 | 150–3200 cm⁻¹ | < 8 cm⁻¹ | TE-cooled back-illuminated CCD | 2000 × 256 | 15 × 15 µm | −60 °C | 10 ms – 60 s |
785 nm
Laser power ≥ 350 mW, 0–100 % continuously adjustable · linewidth < 0.1 nm
FI785E10-Pro-M2
- Spectral range
- 150–2000 cm⁻¹
- Resolution
- < 5 cm⁻¹
- Detector
- TE-cooled back-illuminated CCD
- Effective pixels
- 2048 × 122
- Pixel size
- 12 × 12 µm
- Cooling (typ.)
- −10 °C
- Integration time
- 10 ms – 30 s
FI785E10W-Pro-M2
- Spectral range
- 150–3200 cm⁻¹
- Resolution
- < 10 cm⁻¹
- Detector
- TE-cooled back-illuminated CCD
- Effective pixels
- 2048 × 122
- Pixel size
- 12 × 12 µm
- Cooling (typ.)
- −10 °C
- Integration time
- 10 ms – 30 s
FI785E60-Pro-V2
- Spectral range
- 150–2200 cm⁻¹
- Resolution
- < 6 cm⁻¹
- Detector
- TE-cooled back-illuminated CCD
- Effective pixels
- 2048 × 122
- Pixel size
- 12 × 12 µm
- Cooling (typ.)
- −10 °C
- Integration time
- 10 ms – 30 s
FI785T-Pro
- Spectral range
- 150–2000 cm⁻¹
- Resolution
- < 5 cm⁻¹
- Detector
- NIR-enhanced back-illuminated CCD
- Effective pixels
- 2048 × 64
- Pixel size
- 12 × 12 µm
- Cooling (typ.)
- −10 °C
- Integration time
- 10 ms – 30 s
| Model | Spectral range | Resolution | Detector | Effective pixels | Pixel size | Cooling (typ.) | Integration time |
|---|---|---|---|---|---|---|---|
| FI785E10-Pro-M2 | 150–2000 cm⁻¹ | < 5 cm⁻¹ | TE-cooled back-illuminated CCD | 2048 × 122 | 12 × 12 µm | −10 °C | 10 ms – 30 s |
| FI785E10W-Pro-M2 | 150–3200 cm⁻¹ | < 10 cm⁻¹ | TE-cooled back-illuminated CCD | 2048 × 122 | 12 × 12 µm | −10 °C | 10 ms – 30 s |
| FI785E60-Pro-V2 | 150–2200 cm⁻¹ | < 6 cm⁻¹ | TE-cooled back-illuminated CCD | 2048 × 122 | 12 × 12 µm | −10 °C | 10 ms – 30 s |
| FI785T-Pro | 150–2000 cm⁻¹ | < 5 cm⁻¹ | NIR-enhanced back-illuminated CCD | 2048 × 64 | 12 × 12 µm | −10 °C | 10 ms – 30 s |
1064 nm
Laser power ≥ 350 mW, 0–100 % continuously adjustable · linewidth < 0.1 nm
FI1064E20-Pro
- Spectral range
- 200–2500 cm⁻¹
- Resolution
- < 14 cm⁻¹
- Detector
- TE-cooled InGaAs line array
- Effective pixels
- 512 × 1
- Pixel size
- 25 × 500 µm
- Cooling (typ.)
- −20 °C
- Integration time
- 10 ms – 60 s
| Model | Spectral range | Resolution | Detector | Effective pixels | Pixel size | Cooling (typ.) | Integration time |
|---|---|---|---|---|---|---|---|
| FI1064E20-Pro | 200–2500 cm⁻¹ | < 14 cm⁻¹ | TE-cooled InGaAs line array | 512 × 1 | 25 × 500 µm | −20 °C | 10 ms – 60 s |
Technical Specifications
Common to All Configurations
| Parameter | Specification |
|---|---|
| Excitation | 532 nm (≥ 100 mW) · 785 nm (≥ 350 mW) · 1064 nm (≥ 350 mW); one per instrument, 0–100 % adjustable |
| Laser linewidth | < 0.05 nm (532 nm) · < 0.1 nm (785 / 1064 nm) |
| Spectral range | 150–5000 cm⁻¹ at most, by model (see configurations) |
| Spectral resolution | < 5 cm⁻¹ to < 14 cm⁻¹, by model (see configurations) |
| A/D conversion | 16-bit |
| Interface | USB 2.0 |
| Objective | Standard single lens plus 50× microscope objective |
| Sample monitoring | Built-in camera path, automatically moved in and out of the beam |
| Software | INScan-Lite; optional spectral database |
| Options | Horizontal light path for vials and tubes; 96-well plate stage |
| Power | 100–240 V AC, 50–60 Hz adaptor; 12–24 V DC at 2 A to the instrument |
| Dimensions | 280 × 450 × 200 mm (excluding microscope) |
| Weight | 8 kg (excluding microscope) |
Final specifications depend on the selected model and accessories.
Applications
Where the Finder Insight Pro Is Used
- Biomedicine
- Polymer chemistry
- Environmental science
- Materials science
- Geological science
- Cultural-relic identification and restoration
- Criminal investigation and drug identification
Choosing a Raman System
Need Higher Resolution or Mapping?
RTS-mini
Confocal Raman module for an upright microscope with a 320 mm spectrograph: < 1.5 cm⁻¹ resolution, 80 cm⁻¹ low-wavenumber reach and Raman mapping.
View productFinder 930
Fully automatic confocal platform with up to three software-switched lasers, a motorised mapping stage and cryostat, high-pressure and electrochemical accessories.
View productNew to the technique? Start with the confocal Raman knowledge base.